loading

PPE Testing Equipment Manufacturer | Safety Equipment Testing Machines | GESTER


Products

Analysis of KP95 masks on GB2626 standard detection

When we are buying masks and protective equipment, have you noticed the above implementation standards? Of course, a safe and qualified product is indispensable for these industry standards. What are the production and testing standards for mask products in our country? Let’s take a look Check it out! What are the standards for masks kp95gb2626 masks? At present, my country's main standards for masks include GB 2626-2006 'Respiratory Protective Equipment Self-priming Filter Type Anti-Particulate Respirator', GB 19083-2010 'Technical Requirements for Medical Protective Masks', YY 0469-2011 'Technical Requirements for Medical Surgical Masks' , GB/T 32610-2016 'Technical Specifications for Daily Protective Masks', etc., which are currently mainly divided into three categories: labor protection, medical protection, and daily protection. At present, the common masks in China are basically four standard systems: national standard, American standard, EU standard and Japanese standard. Note: The ones beginning with YY represent the pharmaceutical industry standard, and those beginning with GB represent the national standards, that is, the national standard. 1. The labor protection mask standard GB 2626-2006 'Respiratory Protective Equipment Self-priming Filter Type Anti-Particulate Respirator' was announced by the former General Administration of Quality Supervision, Inspection and Quarantine and the National Standardization Administration. It is a full-text mandatory standard and was implemented on December 1, 2006. The protection objects specified in this standard include various types of particulate matter, including dust, smoke, mist and microorganisms. It also specifies the production and technical specifications of respiratory protective equipment. Dust resistance rate), breathing resistance, testing methods, product identification, packaging, etc. have strict requirements. The standard divides masks into three grades: 90 (KN90, KP90), 95 (KN95, KP95), and 100 (KN100, KP100) according to their filtering efficiency. GB 2626-2019 Respiratory Protection Self-Priming Filtering Anti-Particulate Respirator, the revised version of the standard GB 2626-2019 'Respiratory Protection Self-Priming Filtering Anti-Particulate Respirator' was officially released on December 31, 2019, and is scheduled to be released in 2020 Officially implemented on July 1, 2009, the new standard adds requirements for respirator materials and leak detection methods for detachable parts of products. 2. Medical and health mask standards China currently has two standards for medical protective masks. YY0469-2011 'Medical Surgical Masks' and GB19083-2010 'Technical Requirements for Medical Protective Masks' The detection of medical masks involves three existing national standards: YY/T 0969-2013 'Disposable Medical Masks', YY 0469-2011 'Medical Surgical Masks', GB 19083-2010 'Technical Requirements for Medical Protective Masks'. YY 0469-2011 'Technical Requirements for Medical Surgical Masks' was issued by the State Food and Drug Administration as a standard for the pharmaceutical industry and was implemented on January 1, 2005. This standard specifies the technical requirements, test methods, signs and instructions for use, packaging, transportation and storage of medical surgical masks. The standard stipulates that the bacterial filtration efficiency of masks should not be less than 95%. GB 19083-2010 'Technical Requirements for Medical Protective Masks' was announced by the former General Administration of Quality Supervision, Inspection and Quarantine and the National Standardization Administration and implemented on August 1, 2011. This standard specifies the technical requirements, test methods, signs and instructions for use of medical protective masks, as well as packaging, transportation and storage. It is suitable for filtering particulate matter in the air, blocking droplets, blood, body fluids, secretions, etc. in a medical working environment. Self-priming filter medical protective mask. 4.10 of the standard is recommended, and the rest are mandatory. YY/T 0969-2013 'Disposable Medical Masks', disposable medical masks are tested according to YY/T 0969-2013 standards. Although they are disposable products, their protective effect is not worse than that of protective masks. Standard YY /T 0969-2013 is also very strict on the filtration efficiency of bacteria. 3. The standard for daily protective masks GB/T 32610-2016 'Technical Specifications for Daily Protective Masks' was issued by the former General Administration of Quality Supervision, Inspection and Quarantine and the National Standardization Administration. It is the first national standard for civilian protective masks in my country. implemented on the day. The standard involves mask raw material requirements, structural requirements, labeling requirements, appearance requirements, etc. The main indicators include functional indicators of particulate matter filtration efficiency, expiratory and inspiratory resistance indicators, and tightness indicators. The standard requires that masks should be able to safely and firmly protect the mouth and nose, and there should be no sharp corners and sharp edges that can be touched, and detailed provisions are made on factors that may cause harm to the human body, such as formaldehyde, dyes, and microorganisms, so as to ensure that the public wears them. Safety while protective masks. T/CNTAC 55-2020, T/CNITA 09104-2020 'Civil Sanitary Mask' group standard, in March 2020, the 'Civilian Sanitary Mask' group standard led by China Industrial Textile Industry Association was officially released. The release of this standard fills the gap in the standard in the field of domestic sanitary masks in my country, and changes the current situation that the market has no standard to follow and no standard to check. 13 standard indicators escort the performance of masks. The standard masks are divided into adult masks and children's masks. The specifications are divided into three categories: large, medium and small, which can effectively block the spread of particles such as droplets, pollen, and microorganisms, and the bacterial filtration efficiency is not less than 95%.The particle filtration efficiency is not less than 90%, which is not only suitable for resumption of work and school, but also meets the requirements of the public for personal protection in daily life after the epidemic. In addition to this national standard, there is also a group standard TAJ1001-2015 'PM2.5 protective masks' proposed by the China Textile Business Association, which is compiled for haze protection. Applicable scenarios for masks: Medical disposable masks: worn in ordinary medical environments to block the exhalation or exhalation of pollutants from the oral or nasal cavity. Medical surgical masks: worn by clinical operators during invasive operations and other processes. Medical protective mask: It is a medical protective mask with a higher level of protection. In the medical working environment, it filters particulate matter in the air and blocks droplets, blood, body fluids, secretions, etc. It is worn by medical staff in special areas of isolation wards, isolation intensive care, and fever clinics.

GESTER International Co.,Limited thinks that effective market design can improve liquidity, efficiency, and equity in markets.

GESTER International Co.,Limited seeks to lead the industry by instilling pride in our customers, creating value for the market and sharing responsibility around the world.

tensile tester manufacturers needs not be tedious anymore with the application of . So getting the right textile testing equipment can drastically promote tensile tester manufacturers.

Always put quality over cost is the rule of thumb if you want to buy a really durable and reliable . But with GESTER International Co.,Limited, you can have the same.

We began investing in our workforce and negotiated deals with major suppliers and providers to lower the cost of equipment so the technicians could enhance the competitiveness of textile testing equipment right away.

GET IN TOUCH WITH Us
recommended articles
Glove Tester: Key Standards EN 388 & EN 407
Protective glove testing is the core link to verify hand safety protection performance for industrial PPE. This article focuses on the two most authoritative EU mandatory standards EN 388 and EN 407, elaborates on standardized test necessity, complete test items, professional supporting glove testers, result rating rules, and the differences between mechanical risk testing and thermal risk testing. It provides one-stop compliant testing reference for glove manufacturers, third-party testing labs, and safety supervision institutions to meet global CE certification and workplace safety production requirements.
Sweating Guarded Hotplate Buying Guide
Choosing the right Sweating Guarded Hotplate is essential for obtaining accurate thermal resistance (Rct) and water vapor resistance (Ret) data for textiles. This guide explains how Sweating Guarded Hotplate testing works, introduces international standards including ISO 11092 and ASTM F1868, compares the most important purchasing considerations, and answers common questions from textile laboratories and apparel manufacturers.
How to Choose the Right Glove Testing Equipment
Choosing the right glove testing equipment is essential for evaluating the safety, durability, and protective performance of gloves. This guide explains the main types of glove testing equipment, including thermal protection, cut and abrasion resistance, tensile strength, and environmental conditioning equipment. It also introduces key glove testing standards such as EN 388, EN ISO 13997, ISO 37, ASTM D412, ISO 12947, and related thermal protection standards. By understanding your testing requirements, applicable standards, sample conditioning needs, maintenance requirements, and budget, you can build a more efficient and standard-compliant glove testing laboratory.
Different Types of Cutting Tester: How to Choose the Best for Your Glove Testing?
Cutting testers are essential laboratory instruments used to evaluate the cut-resistance performance of safety gloves, protective fabrics, shoe uppers, composite materials, and other safety-related products. They provide controlled and repeatable testing conditions for product certification, quality control, and research and development. This article explains the main types of cutting testers, including the GT-KC29 Safety Glove Cutting Tester and GT-KC28 TDM 100 Cut Test Machine. It also covers their applications, supported cut-resistance testing standards, key features, data-processing capabilities, maintenance considerations, and important factors to consider when selecting a cutting tester. By understanding the differences between cutting tester types and their applicable standards, laboratories and manufacturers can select equipment that better matches their testing requirements and quality-control objectives.
What is EN 149 & Why is it Important?
EN 149 is the core European standard for particle-filtering half masks and FFP respirators. This article elaborates on the definition, structure, performance classification, marking rules and core advantages of EN 149, compares it with NIOSH N95, KN95, EN 143 and medical mask standards, and lists industry application scenarios, as well as professional mask and filter testing instruments compliant with EN 149 testing requirements.
 Fabric Pilling Test: How to Choose the Right ICI Pilling Box Tester GT-C18
Fabric pilling directly affects the appearance, durability, and perceived quality of textile products. With global textile brands enforcing stricter testing standards, reliable laboratory testing equipment has become essential for manufacturers. This article explores how fabric pilling tests are conducted and why textile laboratories increasingly invest in professional ICI pilling box testers such as the GT-C18. It explains the advantages of in-house testing, international compliance requirements, key machine components, and important parameters buyers should evaluate before purchasing a pilling tester. By selecting the right equipment, textile companies can achieve faster quality verification, reduce dependence on third-party laboratories, and ensure their fabrics consistently meet international market standards.
PPE Testing Laboratory Equipment List
Setting up a PPE testing laboratory requires the right combination of instruments for safety footwear, gloves, protective clothing, masks and safety helmets. This guide explains the core testing equipment used in modern PPE laboratories, the standards they support, and the functions of each instrument, helping manufacturers, third-party laboratories and certification bodies choose a reliable and compliant testing setup.
What Is Martindale Test Equipment? A Practical Guide to Its Role in Safety Gloves
Martindale test equipment is widely used to evaluate the abrasion resistance and pilling performance of textile-based safety-glove materials. This practical guide explains the Martindale abrasion test method, key technical features, applicable Martindale abrasion test standards, and the role of Martindale testers in EN 388 compliance and industrial quality control. It also covers important considerations for laboratories and safety-glove manufacturers when selecting Martindale abrasion testing equipment, including test accuracy, repeatability, mechanical stability, test modes, and long-term operation.
ISO 20345 vs ASTM F2413: Differences Between Safety Footwear Standards
ISO 20345 and ASTM F2413 are the two most recognized safety footwear standards used worldwide to evaluate protective footwear performance. Although both standards define minimum requirements for impact resistance and compression protection, differences in test energy levels, compression loads, marking systems, and hazard classifications can affect certification results. This article explains the key differences between ISO 20345 and ASTM F2413, helping footwear manufacturers, exporters, and quality control teams select the correct testing standard and improve compliance with international safety requirements.
What is the Safety Footwear Impact Tester & Why are They Important in Safety Shoes Testing
A Safety Footwear Impact Tester evaluates the impact resistance of safety shoes by striking the steel toe cap with 100J/200J kinetic energy, ensuring compliance with global standards (EN ISO 20344, ASTM F2412). It’s critical for verifying product protection, facilitating certification, and optimizing safety shoe design. GESTER Instruments offers reliable, user-friendly testers trusted by manufacturers and labs worldwide.
GESTER International Co., Ltd. gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059983973
Address:  No.15, Chifeng Road,Licheng Region, Quanzhou city of Fujian,PR China.
Customer service
detect