Analysis of Test Experiment of Moisture Resistance Microbial Penetration Tester

The moisture barrier microbial penetration tester is used to determine the performance of materials in resisting the penetration of bacteria in liquids when subjected to mechanical friction (the shielding performance against penetration of bacteria carried by liquids when subjected to mechanical friction), mainly used for medical surgical drapes, surgical gowns And clean clothes, etc., (Hong Kong) Co., Ltd. is a manufacturer, and customers in need are welcome to inquire. Applicable standards: YY/T 0506.2, YY/T 0506.6-2009, EN ISO 22610 Main parameters: 1. Turntable speed: (60±1) rpm/min; 2. Test pressure: 3N±0.02N; 3. Outward wheel speed: 5~6rpm; 4. Timer setting range: 0~99.99min; 5. Total weight of inner and outer rings: 800g±1g. Test experiment: There are 5 major steps in the test experiment: The first step: preparation of bacterial slices Staphylococcus aureus ATCC29213 on tryptic soy agar at 36°C±Incubate at 1°C for 18-24h, inoculate 2-3 colonies into 3ml of tryptic soy broth, and inoculate at 36°C±Incubate at 1°C for 18-24h. Dilute 1:10 with peptone water to a concentration of 1×104CFU/mL~4×104CFU/mL, count the bacterial suspension. Open the sterile bag and take out the polyurethane film still attached to the IQ, and place the wettable polyurethane film of the bacteria-carrying material sheet face up on the cleanliness plate. For ease of operation, cover the four corners of the bacteria-carrying material sheet with double-sided tape fixed on the plate. Use the petri dish cover as a template to form a corresponding area on the biofilm, apply 1.0 ml of Staphylococcus aureus suspension to this area, and then dry the bacterial sheet at 56°C for about 30min, using sterile glass during the drying period. The applicator continues to coat the bacterial suspension on the bacterial carrier film to make the bacterial liquid evenly distributed. Use the same day after preparation. The second step: state adjustment If necessary, adjust the state of the specimen according to GB6529, or perform state and state tests under standard normal room temperature conditions. The method of state adjustment shall be recorded in the test report. The third step: test setting Adjust the weight on the control rod, so that the force value applied by the test finger to the agar is 3N±0.02N. Place an agar petri dish on the turntable. Step 4: Material Application Use the following counts: Use a circular weight composed of inner and outer rings, with a total weight of 800g±1g applies a standard taut force to the material. Place the cylinder in the center of the inner ring, then cover the test piece on the cylinder and the inner ring, and place the stained side of the bacterial sheet after removing the sticker paper down on the test piece. Cover a layer of HDPE film on the polyurethane film, push down the outer ring tightly, so that the three-layer material is firmly added between the two rings. Step 5: Carry out the test. Gently place the above ring assembly on an agar petri dish with the lid removed. The steel ring is freely suspended on the outside of the rotating disk. This allows the test piece to come into contact with the agar surface. The test finger is to apply 3N pressure according to the above regulations, and the instrument runs for 15min. Remove the ring kit immediately after 15 minutes and set aside. Remove a petri dish from the carousel and place the lid on. Immediately place the second Petri dish and ring kit on the rotating plate. Perform the above steps with the same ring assembly for the next four Petri dishes. After the five petri dishes have completed the test, remove the bacterial slices and discard them, invert the specimen, and cover it with HDPE film upside down. Operate on the sixth petri dish for 15 minutes to complete a parallel test group. For the remaining 4 specimens, run six petri dishes for 15 min each according to the above method, and use a freshly prepared bacterial slice for each specimen. If there is liquid accumulated on the surface of the agar, put it on a clean bench to dry, cover each agar petri dish and place it at 36°C±Incubate at 1°C for 48h. Count the number of Staphylococcus aureus colonies in each petri dish, and the number of colonies within a radius of 15 minutes from the center of the petri dish is not counted.

GESTER International Co.,Limited, as well, confirms that consumers who want ethically produced goods do the work of looking for them.

To live healthy, you need to eat healthy; to eat healthy, you need to think healthy; to think healthy, you need to read health; to read healthy, you need to follow GESTER Instruments.

The proprietor has many years experience in providing promotion services and is a sought after expert in textile testing equipment.

If you are looking for best product, then here are some product like textile testing equipment, tensile tester manufacturers and tensile tester manufacturers in various styles which will surely meet your demand. Visit GESTER Instruments to know more!

The manufacturing industry is changing fast, so, for GESTER International Co.,Limited, being able to pivot and adapt as the marketplace shifts is imperative.

GET IN TOUCH WITH Us
recommended articles
What is EN 149 & Why is it Important?
EN 149 is the core European standard for particle-filtering half masks and FFP respirators. This article elaborates on the definition, structure, performance classification, marking rules and core advantages of EN 149, compares it with NIOSH N95, KN95, EN 143 and medical mask standards, and lists industry application scenarios, as well as professional mask and filter testing instruments compliant with EN 149 testing requirements.
Why is TPP Testing Important for Firefighter Protective Clothing
TPP testing objectively evaluates the thermal protective performance of firefighter protective clothing under extreme radiant and convective heat. This article explains TPP testing principles, its role in meeting NFPA/ISO standards, and how advanced equipment like the GT-RC02 TPP tester helps ensure clothing reliability and firefighter safety.
GESTER's Success at Shoes & Leather - Vietnam 2025
GESTER successfully participated in Shoes & Leather Vietnam 2025 (July 9-11), showcasing cutting-edge footwear testing machines. Visitors explored equipment like the Bally Resistance Flexing Tester and Martindale Abrasion Tester, with many expressing strong collaboration interest. Learn more about GESTER’s innovative solutions for the footwear industry.
What is the Safety Footwear Impact Tester & Why are They Important in Safety Shoes Testing
A Safety Footwear Impact Tester evaluates the impact resistance of safety shoes by striking the steel toe cap with 100J/200J kinetic energy, ensuring compliance with global standards (EN ISO 20344, ASTM F2412). It’s critical for verifying product protection, facilitating certification, and optimizing safety shoe design. GESTER Instruments offers reliable, user-friendly testers trusted by manufacturers and labs worldwide.
Why TDM Cut Test Machine GT-KC28 Is Needed in PPE Testing

Cut resistance is one of the most critical performance indicators in personal protective equipment (PPE) testing, directly affecting worker safety in high-risk industries such as metal processing, machinery manufacturing, and emergency rescue. The TDM Cut Test Machine GT-KC28 plays a vital role in accurately evaluating the cut resistance of PPE products, including gloves, protective clothing, footwear materials, composite materials, rubber, and industrial textiles.

By adopting high-precision force control systems, intelligent data processing, and stable transmission technology, the GT-KC28 TDM Cut Tester can accurately measure the critical cutting force of materials and ensure excellent repeatability and comparability of test results. Its user-friendly touch-screen operation, comprehensive data storage, USB data export, and built-in thermal printer greatly improve laboratory efficiency and data traceability.

The TDM Cut Test Machine GT-KC28 fully complies with major international and national standards such as ISO 13997, EN 388, ASTM F2992/F2992M, ANSI/ISEA 105, and GB 24541-2022, making it a reliable solution for PPE manufacturers, third-party testing laboratories, and research institutions. Through precise and standardized cut resistance testing, the GT-KC28 helps reduce industrial cutting injuries, supports PPE certification across global markets, and ensures that protective equipment delivers reliable safety performance in real-world applications.
Safety Footwear Test Explained: Compression and Puncture Tester
This article fully explains the working principle, applicable international standards, test advantages and application scope of safety footwear compression and puncture tester GT-KB12A. It covers core protective performance testing of safety shoe toecap and sole steel plate, complies with GB, ISO, EN, ASTM and other global standards, and serves manufacturers, third-party labs and safety footwear R&D institutions for quality control .
How to Choose Light Fastness Tester: Water-Cooled and Air-Cooled
Choosing between water-cooled and air-cooled light fastness testers depends on precision needs, budget, and application. Water-cooled testers (like GESTER GT-3000) offer superior spectral accuracy and stability for rigorous standards (e.g., automotive, coatings). Air-cooled models (like GESTER GT-D02A-1) provide energy efficiency and easier installation for routine QC. This guide compares cooling methods, features, and applications to help you select the optimal tester.
ISO 20344 Tester – Tested by ISO 20344 Standard
EN ISO 20344 is the core international test method standard for full-performance detection of safety footwear. This article systematically explains the full range of whole-shoe test items covered by the ISO 20344 standard, analyzes the core practical advantages of mandatory ISO 20344 testing for factories and laboratories, and matches a complete set of dedicated ISO 20344 testers one by one. It also sorts out mainstream associated safety footwear standards worldwide, providing one-stop standardized testing solutions for safety footwear manufacturers, third-party testing institutions and occupational safety supervision departments.
Bally Leather Flexing Tester GT-KC10A Assembly Guide
This comprehensive guide provides detailed instructions for the proper assembly, calibration, and operation of the Bally Leather Flexing Tester GT-KC10A. Essential for quality control labs, it ensures accurate testing of flex resistance in leather, coated fabrics, and textiles used in footwear uppers, helping to prevent material failure.
Leather Physical Properties Testing Guide
This guide details the 9 critical physical property tests essential for assessing leather quality: Tensile Strength, Tear Strength, Abrasion Resistance, Thickness, Water Vapor Permeability, Water Resistance, Shrinkage Temperature, Color Fastness to Friction, and Bending Strength. It covers the testing scope (natural leather, synthetic leather, finished products, semi-finished goods) and introduces specialized testing equipment required for each method (e.g., Universal Testing Machine, Elmendorf
GESTER International Co., Ltd. gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059985379
Address:  Block 402,4th floor, f buliding, shengfulan business Center, no.577 jitai road, economic and  Technological development zone quanzhou of fujian.China.
Customer service
detect