loading

GESTER PPE Testing Equipment | Professional Safety Footwear Testing Equipment, Glove Testing Equipment, Protective Clothing Testing Equipment


Products

Analysis of the test method for atomization performance of automotive interior parts

Through the atomization test of automobile interior decoration materials, the volatile substances in the automobile interior decoration materials can be controlled, thereby effectively reducing the environmental pollution in the automobile. Therefore, atomization test has become an important means for automobile manufacturing enterprises and automobile interior decoration manufacturing enterprises to control product quality. Customers call in time. The atomization tester for automotive interior parts is suitable for interior materials such as automobiles and aircraft, such as automotive interior plastic parts, polyurethane, textiles, leather, adhesives, non-woven fabrics, thermoplastic elastomers and other materials. The evaluation of evaporation can also be used to measure the high temperature fogging phenomenon of front xenon lamps. Applicable standards: DIN75201, ISO6452, ISO17071, SAEJ1756, QB/T2728, BSEN14288, PV3920, PV3015, ES-X83231, NESM0161, D451727, GM9305P, TSM0503G ℃ purchased separately); 2. Temperature control accuracy of high temperature tank:±0.1°C (150°C); 3. Low temperature tank temperature range: 0-100°C; 4. Low temperature tank temperature control accuracy:±0.1℃; 5. Dimensions of high temperature tank: 670mm(L)×490mm(W)×540mm(H); 6. Dimensions of low temperature tank: 400mm(L)×220mm(W)×520mm(H); 7. Net weight of high temperature tank: 32kg (excluding heat transfer medium); 8. Net weight of low temperature tank: 15kg (excluding heat transfer medium); 9. Power requirements: AC220V, single phase, 50-60Hz, 2000W. In addition, the technical engineer said that at present, there are three test methods involved in the fogging test standards for automotive interiors at home and abroad: reflection method, gravimetric method and haze method. These standards and their related test methods are as follows: DIN75201---Reflection method, Gravimetric method SAEJ1756---Reflection method, Gravimetric method ISO6452---Reflection method, Gravimetric method QB/T2728---Reflection method, Gravimetric method NESM0161-- -Haze method ES-X83231---Haze method, gravimetric atomization device The following figure is a schematic diagram of the structure of the atomization device in the atomization test. Place the sample under the sample holder at the bottom of the glass beaker and immerse it in a constant temperature oil bath. The beaker is covered with an oil-resistant and high-temperature-resistant fluorine sealing ring, on which are placed the atomization carrier (G position), filter paper, and cooling plate in turn. The substances released by the leather samples at high temperatures condensed on the cooling plate. Except for position G, the test equipment for these three methods is the same. For the reflection method and the fogging method, part G is the fogging glass plate. The test results are obtained by measuring the haze or haze value of the glass plate before and after the test. In gravimetry, position G is an aluminum foil with a larger circular glass plate 3 mm thick on it. Test results for this method were obtained by measuring the amount of condensate formed on the cold surface. Environmental requirements: As long as the constant temperature tank and the cooling plate can work at the required temperature, the atomization process of the test does not have high requirements on the external environment. The environment fundamentally has no effect on it. However, mist carriers such as aluminum foil and glass plate have strict requirements on the environment, and even the slightest change can have a big impact. In almost all standards, fogged glass panels are required to be placed at 23°C±2°C temperature, and in a windless environment at 50%±Conditioned at 5% relative humidity. There will inevitably be some condensation on the atomized carrier. Ambient temperature and humidity play a crucial role in the evaporation of water, and it is difficult to control the ambient temperature and humidity effectively. The uncertainty of environmental control will directly affect the accuracy of the final test results. In the standard DIN75201, ISO6452 and QB/T2728, it is stipulated that the fogged aluminum foil should be treated in a dryer. In this case, the user simply takes the ambient temperature into account for condensation, and no longer has to consider humidity and airflow. Therefore, the conditioning environment of the misted aluminum foil is easier to control. Calibration of test results: Because the atomization test operation process is complex and easily affected by environmental changes, the three standards of DIN75201, ISO6452 and QB/T2728 provide the same calibration method to evaluate the correctness of the final test results. For the reflection method, put 10±0.1g DIDP into immersion 100°C in a beaker in a constant temperature bath, the cooling plate is 21°C, the final result should be at 77±within 3%. Otherwise, the test is considered unsuccessful. The user should find out why and retest. The weight method will be 10±0.1gDOP into 100°C in a beaker immersed in a constant temperature bath, the cooling plate is 21°C, the final result should be in 4.9±in the range of 0.25 mg. Otherwise, the test is considered unsuccessful. The user should find out why and retest. For the haze method, no calibration method is provided in the above standards. Comparison of the three methods: The following table is a comparison of the three methods items

tensile tester manufacturers textile testing equipment is liked by everyone and is used in every household.

The guiding vision of GESTER International Co.,Limited is 'Bringing the best to everyone we touch'. By 'The best', we mean the best products, the best people and the best ideas.

According to the latest social survey, more than 50 percent of consumers (across all age demographics) follow a brand before purchasing a product. Therefore, GESTER Instruments's content can make or break a customer's decision to conduct business with you.

GET IN TOUCH WITH Us
recommended articles
GESTER: China Top PPE Testing Equipment Company Leading Global Safety Standards
Since 1997, GESTER International Co., Ltd has emerged as China’s top PPE testing equipment company, with 25+ years of R&D experience in high-precision testing instruments. Serving clients in over 160 countries and partnering with global leaders like SGS, Intertek, and TUV, GESTER aligns its products with international standards (ISO, ASTM, EN, GB) to ensure reliable PPE performance. Highlighted by the GT-RC02B TPP Thermal Protection Tester—capable of simulating extreme thermal environments and calculating critical safety metrics like TPP values and escape time—and the GT-KC28 TDM Cut Test Machine, GESTER’s portfolio covers thermal protection, cut resistance, footwear testing, and more. The company offers comprehensive support, including ISO 17025/NFPA-aligned calibration, on-site installation, and staff training, empowering PPE manufacturers and testing laboratories to meet stringent global regulations, prevent workplace injuries, and accelerate market access. As a leader in global safety standards, GESTER combines technical precision, user-centric design, and lifecycle service to deliver tailored solutions for high-risk industries worldwide. Visit https://www.gesterinstruments.com/ for full product details.
Top Features of a Certified TDM Cut Resistance Tester Supplier for Laboratory Use
The demand for precise PPE safety testing has surged with the evolution of protective gear, making TDM (Tomodynamometer) cut resistance testing a critical process for evaluating protective gloves and industrial textiles. This article details the top features of a certified TDM cut resistance tester supplier for laboratory use, including compliance with international standards (EN 388, ISO 13997, ASTM F2992), high-precision mechanical engineering, automated workflows, robust data management, and integrated safety features. It highlights GESTER International Co., Ltd.—a 20+ year experienced manufacturer with ISO 9001 certification and partnerships with SGS, Intertek, and TUV—as a leading supplier, offering the GT-KC28 TDM Cut Test Machine and comprehensive services (on-site installation, calibration, global technical support). For laboratories seeking reliable, standard-compliant testing solutions to validate PPE safety claims, this article provides actionable insights into strategic procurement. Visit https://www.gesterinstruments.com/ for more technical specifications and PPE testing solutions.
According to ASTM D642 Standard: Detailed Box Compression Strength Tester GT-N02A
The ASTM D642 standard defines the test method for determining the compressive resistance of shipping containers, like corrugated boxes, when faced with static compressive forces. This article details the test procedure and introduces the GESTER GT-N02A and GT-N02B Box Compression Testers, which are fully compliant with ASTM D642, ISO 12048, and TAPPI T804. These versatile machines perform destructive strength tests, constant value tests, and simulated long-term stacking tests to ensure your pac
Bally Leather Flexing Tester GT-KC10A Assembly Guide
This comprehensive guide provides detailed instructions for the proper assembly, calibration, and operation of the Bally Leather Flexing Tester GT-KC10A. Essential for quality control labs, it ensures accurate testing of flex resistance in leather, coated fabrics, and textiles used in footwear uppers, helping to prevent material failure.
Mask Testing Equipment: Everything You Need to Know
This article comprehensively introduces mask testing equipment, including its definition, application significance, core international testing standards, main equipment types and functional characteristics. It also puts forward a step-by-step selection guide and common selection misunderstandings, providing a reference for mask manufacturers, third-party testing institutions and regulatory departments to select appropriate testing equipment, so as to ensure mask product quality, pass international certification and protect user safety.
Analysis of Pilling Influencing Factors and Testing Methods
Pilling testing plays a vital role in textile quality control, helping manufacturers evaluate and improve the wear performance of fabrics. Through the use of advanced instruments like ICI Pilling Box Test Method (GT-C18) , Martindale Abrasion Test Method (GT-C13B) , and Random Tumble Pilling Test Method (GT-C19A) , laboratories can conduct precise and standardized assessments, ensuring that final textile products deliver superior appearance, comfort, and longevity.
What is EN 149 & Why is it Important?
EN 149 is the core European standard for particle-filtering half masks and FFP respirators. This article elaborates on the definition, structure, performance classification, marking rules and core advantages of EN 149, compares it with NIOSH N95, KN95, EN 143 and medical mask standards, and lists industry application scenarios, as well as professional mask and filter testing instruments compliant with EN 149 testing requirements.
Looking for a Laboratory Protective Clothing Tester Supplier? Key Criteria to Consider
As global demand for high-performance PPE surges, selecting a qualified laboratory protective clothing tester supplier becomes critical for manufacturers and regulators. This article outlines core selection criteria: compliance with international standards (ISO, EN, ASTM), comprehensive protective gear tests (particle resistance, fluid barrier, thermal resistance, electrostatic safety), manufacturer qualifications (ISO 9001 certification, partnerships with SGS/TUV/Intertek), equipment precision (automation, modular design, data traceability), and end-to-end service (global support, calibration, customization). With 25+ years of experience, GESTER International delivers standards-aligned, high-precision testing instruments and integrated laboratory solutions, ensuring PPE meets rigorous safety requirements for medical, industrial, and chemical sectors. Explore how to choose a partner that safeguards worker safety through reliable testing.
Glove Tester: Key Standards EN 388 & EN 407
Protective glove testing is the core link to verify hand safety protection performance for industrial PPE. This article focuses on the two most authoritative EU mandatory standards EN 388 and EN 407, elaborates on standardized test necessity, complete test items, professional supporting glove testers, result rating rules, and the differences between mechanical risk testing and thermal risk testing. It provides one-stop compliant testing reference for glove manufacturers, third-party testing labs, and safety supervision institutions to meet global CE certification and workplace safety production requirements.
What is the Use of Air Permeability Tester?
An air permeability tester measures how easily air passes through textiles, nonwovens, and other materials, directly impacting comfort (heat/moisture management) and performance (wind resistance, filtration). This guide explains how digital testers work using pressurized airflow, details step-by-step testing procedures (including nozzle selection), and covers key applications in apparel, medical, automotive, and industrial sectors. Explore compliant standards (ISO 9237, ASTM D737, GB/T 5453) and
Quanzhou Gester International Co.,Ltd gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059985379
Address:  Block 402,4th floor, f buliding, shengfulan business Center, no.577 jitai road, economic and  Technological development zone quanzhou of fujian.China.
Customer service
detect