loading

PPE Testing Equipment Manufacturer | Safety Equipment Testing Machines | GESTER


Products

Analysis of YY/T 0631-2008 Test Method for Color Stability of Dental Materials

Scope: This standard specifies a method for the determination of the color stability of dental materials after exposure to water immersion light. Test device: Xenon lamp with medium pressure light source, color temperature between 5000K and 10000K. Measured according to GB16422.2, the illuminance in the sample should reach 150000lx±15000lx. Other light sources equivalent to xenon lamps may also be used. The luminous intensity of xenon lamp and UV filter will change due to aging after 1500 hours of use, and should be replaced in time. Get a suitable illuminometer to measure the illuminance and adjust the contrast accordingly. The UV filter is made of optical glass (borosilicate glass), the transmittance of light waves below 300nm should be less than 1%, and the transmittance of light waves above 270nm should be greater than 90%. Test chamber circulating water bath distilled water or deionized water, the temperature is maintained at (37±5) ℃, the water surface is on the sample (10±5) mm, the sample is placed parallel to the bottom of the testing-equipment' target='_blank'>test chamber. Specimen holders are made of opaque material, preferably metal, and can be used to hold specimens up to 50mm in diameter. Figure 1 shows a suitable specimen holder. Test steps: ① Sample preparation Each dental material standard control sample size, sample preparation method and conditions and the products of the control sample are specified. These standards should be used in conjunction with this standard. ②Half of the irradiated test specimen is clamped with specimen clamps (see detailed standard), or wrapped with tin or aluminum foil. For dental specimens, wrap half of the tooth vestibule with tin or aluminum foil parallel to the long axis of the tooth. Install the UV filter, put the sample into a water bath, and irradiate the sample with a xenon lamp (24±1) h. Take care to avoid shadows on the specimen. Evaluation - Color Comparison: Three examiners with normal color vision, orally observe any difference in color between the irradiated half of the sample and the unirradiated half and from the unirradiated sample. Examiners with normal color vision should be checked and verified by a doctor or other appropriately trained person. Colorless vision correction glasses may be worn. The comparison shall be made under bright diffused sunlight that is not in direct sunlight in the north direction, or under a xenon lamp with an illuminance of 1000 lx~2000 lx or an equivalent lamp conforming to CIED65 without any obvious color reflection. The disk-shaped sample is placed against a diffuse white background with a reflectivity of about 90%. The background is the same size as the disc, and the surrounding reflectivity is (30±5)% diffuse gray background around. Tooth-shaped sample, with reflectivity (30±5)% diffuse gray background. Let three observers observe for no more than 2 s at a distance of 200 mm to 300 mm from the sample. The comparison results of the three observers were recorded separately. If the observation conclusion is in dispute, the majority result shall prevail.

Currently there is a global trend growing. People are more conscious about tensile tester manufacturers and are seeking alternatives to traditional solutions.

Looking for a company to handle your textile testing equipment tensile tester manufacturers? Visit GESTER Instruments today for more information.

A technology team created for insuring that textile testing equipment is produced with the finest materials and technologies.

GET IN TOUCH WITH Us
recommended articles
How to Choose the Right Glove Testing Equipment
Choosing the right glove testing equipment is essential for evaluating the safety, durability, and protective performance of gloves. This guide explains the main types of glove testing equipment, including thermal protection, cut and abrasion resistance, tensile strength, and environmental conditioning equipment. It also introduces key glove testing standards such as EN 388, EN ISO 13997, ISO 37, ASTM D412, ISO 12947, and related thermal protection standards. By understanding your testing requirements, applicable standards, sample conditioning needs, maintenance requirements, and budget, you can build a more efficient and standard-compliant glove testing laboratory.
How to Test Firefighter Turnout Gear Thermal Protection?
Firefighter turnout gear plays a critical role in protecting firefighters operating in extreme environments involving high temperatures, flames, radiant heat, and convective heat. Its thermal protective performance directly affects firefighter safety and survival during fireground operations. This article explains how to test firefighter turnout gear thermal protection through Thermal Protective Performance (TPP) testing. It introduces the scientific principle based on the Stoll curve, outlines key influencing factors such as heat flux intensity and exposure time, and reviews internationally recognized standards including NFPA 1971 and ISO 17492. The article also highlights the testing advantages of the GT-RC02 TPP Thermal Protection Tester, which provides accurate, stable, and standards-compliant evaluation of flame-retardant protective clothing materials under combined radiant and convective heat exposure.
Top Features of a Certified TDM Cut Resistance Tester Supplier for Laboratory Use
The demand for precise PPE safety testing has surged with the evolution of protective gear, making TDM (Tomodynamometer) cut resistance testing a critical process for evaluating protective gloves and industrial textiles. This article details the top features of a certified TDM cut resistance tester supplier for laboratory use, including compliance with international standards (EN 388, ISO 13997, ASTM F2992), high-precision mechanical engineering, automated workflows, robust data management, and integrated safety features. It highlights GESTER International Co., Ltd.—a 20+ year experienced manufacturer with ISO 9001 certification and partnerships with SGS, Intertek, and TUV—as a leading supplier, offering the GT-KC28 TDM Cut Test Machine and comprehensive services (on-site installation, calibration, global technical support). For laboratories seeking reliable, standard-compliant testing solutions to validate PPE safety claims, this article provides actionable insights into strategic procurement. Visit https://www.gesterinstruments.com/ for more technical specifications and PPE testing solutions.
What is EN 149 & Why is it Important?
EN 149 is the core European standard for particle-filtering half masks and FFP respirators. This article elaborates on the definition, structure, performance classification, marking rules and core advantages of EN 149, compares it with NIOSH N95, KN95, EN 143 and medical mask standards, and lists industry application scenarios, as well as professional mask and filter testing instruments compliant with EN 149 testing requirements.
Leather Industry Innovations: GESTER at ACLE as a Footwear Testing Equipment Factory
The global leather and footwear industry is shifting toward prioritizing durability, material integrity, and functional excellence—driving demand for high-precision testing equipment. As a highlight of ACLE 2026 (All China Leather Exhibition), GESTER International Co., Ltd., a 25+ year footwear testing equipment factory, showcases innovative solutions tailored to this trend. Trusted by leading testing institutes like SGS, TUV, and Intertek, GESTER’s product lineup includes the Martindale Abrasion Tester (for surface durability), Tension Testing Machine (for mechanical properties), and Safety Shoe Cutting Tester—all compliant with ISO, ASTM, and EN standards. These instruments integrate automation (PLC systems) and data traceability to reduce human error, support ISO 9001 compliance, and streamline laboratory efficiency. With a global service network spanning 160+ countries, GESTER offers on-site installation, calibration, and software updates to ensure long-term usability. The article also outlines strategic procurement tips for manufacturers, emphasizing modular design, standard compatibility, and supplier track records. For leather and footwear brands seeking to enhance product reliability, avoid recalls, and stay competitive, GESTER’s ACLE 2026 innovations and end-to-end support provide a definitive quality assurance solution.
Why Is Shoe Slip Resistance Tester Important for Footwear Safety?
Slip resistance is one of the most critical performance indicators for modern footwear, especially safety shoes used in industrial and high-risk working environments. Slip and fall accidents frequently occur on wet or smooth surfaces, posing serious risks to workers and consumers. To prevent such accidents and improve product safety, footwear manufacturers widely use professional testing equipment such as Shoe Slip Resistance Tester and Footwear Slip Testing Machine. These devices simulate real walking conditions to measure the coefficient of friction between the shoe sole and various surfaces. This article explores the working principle, features, applications, and industry significance of shoe slip safety tester, explaining why accurate slip resistance testing is essential for footwear safety, product development, quality control, and compliance with international standards.
Safety Footwear Tester Guide ISO 20346 with Buying Tips
This guide explains the ISO 20346 standard for general-purpose protective footwear, differentiates it from related ISO standards, and shares core buying tips for qualified safety footwear testers. It also introduces professional multi-standard compliant testing equipment for footwear quality control and compliance verification.
How to Choose the Right Safety Shoes Testing Equipment Supplier?
Safety shoes are essential personal protective equipment (PPE) in high-risk industries. To ensure compliance with international standards such as EN ISO 20345 and ASTM F2413, professional testing equipment is required. This article explains common safety shoes test items, corresponding testing machines, and how to choose a reliable safety shoes testing machine supplier. It also analyzes key factors such as technical capability, standard compliance, equipment stability, and cost performance to help enterprises build a strong quality control system and enhance global competitiveness.
DIN Abrasion Tester vs Taber Abraser: What Is the Difference?

Choosing the right abrasion testing equipment is essential for obtaining accurate and repeatable wear resistance results. DIN Abrasion Tester and Taber Abrasion Tester are two widely used abrasion testing machines, but they are designed for different material types and testing purposes.

This article provides a detailed comparison between DIN Abrasion Tester and Taber Abraser, covering their working principles, specimen requirements, industry applications, standard compliance, technical characteristics, operation features and practical advantages. DIN Abrasion Tester is mainly designed for rubber, elastic materials, tires, conveyor belts and footwear soles, while Taber Abrasion Tester is suitable for flat materials such as coatings, textiles, plastics, leather, metals and decorative surfaces.

By understanding the differences between these two abrasion testing methods, laboratories can select the most suitable abrasion tester based on sample geometry, testing standards and production quality control requirements.
Which Safety Footwear Test Method Is Suitable for You?
Selecting the correct safety footwear test method is essential for ensuring product durability, worker protection, and international compliance. Different tests evaluate different performance characteristics, including impact resistance, slip resistance, and outsole abrasion. This article explains how each testing method works, the applicable ISO, ASTM, DIN, and SATRA standards, and when manufacturers should use each test to improve product quality, reduce failures, and meet global certification requirements.
GESTER International Co., Ltd. gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059985379
Address:  No.15, Chifeng Road,Licheng Region, Quanzhou city of Fujian,PR China.
Customer service
detect