loading

PPE Testing Equipment Manufacturer | Safety Equipment Testing Machines | GESTER


Products

Interpretation of the flame retardant test process of masks

Test standards This medical mask flame retardant performance tester meets but is not limited to the following standards: GB 19083-2010 technical requirements for medical protective masks; YY 0469-2011 medical surgical masks. GB 2626-2006 'Respiratory protective equipment self-priming filter type anti-particulate respirator' test principle 1. Use standard energy heat source to test the mask to observe the burning behavior of the mask. The energy of the fire source is guaranteed by measuring the height and temperature of the flame. 2. The time for masks or other samples to pass through the fire source is stipulated in the standard, and the action time of the fire source is ensured by controlling the moving speed of the mask. 3. The burning behavior of the sample is measured by the flame burning and flameless burning of the sample. In the test, plug in the power socket on the back cover of the instrument and turn on the power, connect the air inlet to the propane cylinder, and open the gas cylinder valve to connect to the gas source. Close the front door of the combustion test chamber, and place the 'power' switch in the 'on' position, and the power indicator light is on. First make the nose tip of the metal head mold downward, put the mask on the metal head mold, move the head mold slightly with your hands, when the nose tip of the head mold is just above the igniter, adjust the height of the igniter head (turn clockwise) Lower the igniter head, turn the igniter head counterclockwise to raise it) Make the distance between the tip of the igniter and the tip of the nose of the head die 20±2mm and press the 'Igniter Return' button to restore the burner to the ignition position. Press the 'head mold return' button to restore the head mold to the starting position. Press the 'Zero' key, and the instrument will return to the initial state. Keep pressing the 'ignition' button, adjust the propane medium pressure valve 'pressure adjustment' knob (according to the '+' direction at the end of the knob to increase, and the '-' direction to decrease to adjust) to make the pressure gauge pointer on the top of the instrument box Refers to 20kPa. At this time, the ignition resistance wire has turned red. After the igniter is ignited, release the 'ignition' button. When it is difficult to ignite, please adjust the 'flame adjustment' button, the clockwise direction is to reduce the flow of combustible gas, and the counterclockwise direction is to increase the flow of combustible gas. If the ignition fails for some reason, in order to prevent the gas from continuing to pass in and cause an explosion, click 'Continue Burning Stop' to stop the gas, and then click 'Clear' to restore the initial state. Open the front door of the combustion test chamber, place the flame height gauge (height 40mm) directly in front of the flame by hand, turn the 'flame adjustment' knob to adjust the flame height to 40mm±2mm, after the flame stabilizes, remove the flame height gauge. Observe whether the “temperature display” on the panel of the instrument is stable at 800±50℃, if it is not enough, it can be adjusted by increasing the inlet pressure of the gas cylinder pressure reducing valve to stabilize the flame temperature at 800±50℃. Press the 'ignition start' button to move the igniter to the ignition position, press the 'head mold start' button, the head mold starts to rotate, after the head mold rotates in place, the igniter stops gas and resets, and the 'continuous ignition time' is automatic Timing; after the continuous burning, press the 'continuous burning stop' button; if there is no continuous burning, directly press the 'continuous burning stop' button, after the smoldering ends, press the 'smoldering stop' button again, and record the continuous burning time and overcast Burn time. Press the 'head mold return' button to restore the head mold to the starting position, open the front door of the combustion test box to remove the sample, and the test is over. Press the 'clear' button, the instrument will return to the initial state, and the next mask sample will be placed on the metal head mold. At this time, the next test can be carried out according to the steps 6-11. If you don't need the next test, please turn off the power, unplug the power plug, take out the residue container, and clean up the burning residue. If you want to test the flame retardancy of the mask belt, you must put the mask on the metal head mold, loosen the 'head mold positioning screwPress the 'head mold start' button, the head mold starts to rotate, when the head mold is just above the igniter, press the 'smolder stop' button to stop the head mold, adjust the height of the igniter head to make the top of the igniter The distance from the lowest part of the head mold is 20±2mm and the test is carried out according to the steps 6-11. When testing materials, use injection molding, compression molding or compression molding to make the required shape. If the above method is not feasible, a sample should be cut from a representative sample of the material. After the production is completed, use fine sandpaper to smooth each cut surface of the incision, and carefully remove all dust and particles on the surface. The sample size should be at least 60mm long and 60mm wide (inside the fixture). The first xuan thickness values u200bu200binclude: 0.1mm±0.02mm, 0.2mm±0.02mm, 0.4mm±0.05mm, 0.75mm±0.10mm, 1.5mm±0.15mm, 3.0mm±0.2mm or 6.0mm±0.4mm.

The importance of textile testing equipment has increased as tensile tester manufacturers have become a must in our daily life.

Super quality are in offer at GESTER Instruments, welcome to visit us.

Loyalty programs provide an opportunity to learn the preferences of customers and design communication strategies that will resonate with textile testing equipment.

GET IN TOUCH WITH Us
recommended articles
How to Test Firefighter Turnout Gear Thermal Protection?
Firefighter turnout gear plays a critical role in protecting firefighters operating in extreme environments involving high temperatures, flames, radiant heat, and convective heat. Its thermal protective performance directly affects firefighter safety and survival during fireground operations. This article explains how to test firefighter turnout gear thermal protection through Thermal Protective Performance (TPP) testing. It introduces the scientific principle based on the Stoll curve, outlines key influencing factors such as heat flux intensity and exposure time, and reviews internationally recognized standards including NFPA 1971 and ISO 17492. The article also highlights the testing advantages of the GT-RC02 TPP Thermal Protection Tester, which provides accurate, stable, and standards-compliant evaluation of flame-retardant protective clothing materials under combined radiant and convective heat exposure.
10 Benefits of GESTER PPE Testing Equipment You Need to Know
Choosing PPE testing equipment requires more than comparing machine prices. Measurement accuracy, test repeatability, applicable standards, fixture design, automation, calibration, customization and technical support can directly affect laboratory efficiency and testing reliability. GESTER provides integrated PPE testing solutions covering safety footwear, protective gloves, protective clothing, masks and safety helmets. This article explains 10 technical advantages to consider when comparing GESTER PPE Testing Equipment with alternative suppliers.
Safety Footwear Tester Guide ISO 20346 with Buying Tips
This guide explains the ISO 20346 standard for general-purpose protective footwear, differentiates it from related ISO standards, and shares core buying tips for qualified safety footwear testers. It also introduces professional multi-standard compliant testing equipment for footwear quality control and compliance verification.
DIN Abrasion Tester vs Taber Abraser: What Is the Difference?

Choosing the right abrasion testing equipment is essential for obtaining accurate and repeatable wear resistance results. DIN Abrasion Tester and Taber Abrasion Tester are two widely used abrasion testing machines, but they are designed for different material types and testing purposes.

This article provides a detailed comparison between DIN Abrasion Tester and Taber Abraser, covering their working principles, specimen requirements, industry applications, standard compliance, technical characteristics, operation features and practical advantages. DIN Abrasion Tester is mainly designed for rubber, elastic materials, tires, conveyor belts and footwear soles, while Taber Abrasion Tester is suitable for flat materials such as coatings, textiles, plastics, leather, metals and decorative surfaces.

By understanding the differences between these two abrasion testing methods, laboratories can select the most suitable abrasion tester based on sample geometry, testing standards and production quality control requirements.
Whole Shoes Flexing Tester GT-KA01-2: An Ultimate Guide to Its Benefits and Applications
The Whole Shoes Flexing Tester GT-KA01-2 is an advanced footwear testing instrument designed to evaluate the flexing resistance and durability of finished shoes. By simulating repeated walking and bending movements, it helps manufacturers identify cracks, material fatigue, and structural weaknesses in footwear products. Compliant with SATRA TM92, ISO 24266 Method A, and HG/T 2871-2022 Method B, this testing machine provides accurate, repeatable, and reliable results for sports shoes, casual shoes, work shoes, and other footwear types. This guide explores its features, benefits, industry applications, and frequently asked questions to help footwear manufacturers improve product quality and meet international testing requirements.
Sweating Guarded Hotplate Buying Guide
Choosing the right Sweating Guarded Hotplate is essential for obtaining accurate thermal resistance (Rct) and water vapor resistance (Ret) data for textiles. This guide explains how Sweating Guarded Hotplate testing works, introduces international standards including ISO 11092 and ASTM F1868, compares the most important purchasing considerations, and answers common questions from textile laboratories and apparel manufacturers.
What is the Safety Glove & Shoe Upper Cutting Tester GT-KC29
The Safety Glove & Shoe Upper Cutting Tester GT-KC29 is a high-precision testing instrument developed to measure the cut resistance performance of safety gloves and footwear uppers. In industrial and construction environments where sharp tools and metal edges pose significant injury risks, the GT-KC29 provides a reliable evaluation method by simulating real cutting motion. This tester meets EN 388 section 6.2, ISO 20344:2021 section 5.23, GB/T 20991 section 6.14, and other global standards, making it essential for PPE manufacturers, testing laboratories, and quality control departments. With automated operation, high repeatability, and multi-standard compliance, it helps companies improve product safety levels, enhance global competitiveness, and ensure superior protection for end users.
Bally Resistance Flexing Tester – An Effective Method for Testing Material Flexing
The Bally Resistance Flexing Tester, also known as the Bally Leather Flexometer, is an essential testing instrument for evaluating the flex durability of leather, coated fabrics, synthetic leather, and textile materials. By accurately simulating repeated bending conditions encountered during actual use, the tester helps manufacturers assess material performance, prevent premature product failures, and meet international quality standards. This article explores the working principle, key benefits, applicable testing standards, and common specimen materials suitable for Bally flexing resistance testing.
What Are the ISTA Standard Tests and ISTA Testing Equipment?
ISTA (International Safe Transit Association) standard tests are globally recognized transportation packaging test procedures designed to evaluate the safety and reliability of products and their packaging throughout the logistics chain. By simulating real-world transportation conditions such as drops, vibration, impact, stacking, and compression, ISTA testing helps identify potential packaging weaknesses before products enter large-scale distribution. ISTA testing equipment—including drop testers, vibration testers, incline impact machines, and compression testers—plays a critical role in accurately reproducing these conditions under laboratory settings. Proper selection and use of ISTA-compliant equipment enable manufacturers to reduce transportation damage, lower return costs, enhance packaging design, and improve customer confidence in product quality and logistics safety.
What is EN 149 & Why is it Important?
EN 149 is the core European standard for particle-filtering half masks and FFP respirators. This article elaborates on the definition, structure, performance classification, marking rules and core advantages of EN 149, compares it with NIOSH N95, KN95, EN 143 and medical mask standards, and lists industry application scenarios, as well as professional mask and filter testing instruments compliant with EN 149 testing requirements.
GESTER International Co., Ltd. gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.