The construction of a professional laboratory is not just a simple combination of equipment and furniture, it is a complex system engineering and a construction with strict requirements for the working environment. What are the laboratory construction steps? The laboratory design company will carry out laboratory construction according to the following steps. 1. Laboratory construction planning The laboratory construction planning includes the appearance, style, height, layout, etc.; before the construction of the laboratory, it is necessary to understand the needs of customers and the future development direction and combine the laboratory construction experience of other related industries to be unified and reasonable. planning. 2. The laboratory plan design uses professional means to carry out the process of concrete realization of the plan roots, including laboratory design, installation, commissioning, maintenance and upgrades. 3. Selection of laboratory construction unit The laboratory design and construction unit should choose a domestic enterprise with a certain scale. The company's strength and level must be strictly inspected, and it is best to inspect its completed successful cases and the location of the company on the spot. 4. The design of the laboratory layout. The layout design stage of the laboratory should consider the needs of work and development as much as possible, rationally allocate the space, and optimize the integration as much as possible. The complete layout of the laboratory can ensure the subsequent professional design of water, electricity, and wind. 5. Laboratory power distribution system The power distribution system of the laboratory is designed according to the specific requirements of the experimental instruments and equipment, through the comprehensive design of professional designers. Because the requirements of laboratory equipment for circuits are more complex, the design of the power distribution system should not only consider the existing equipment and equipment, but also consider the development direction of the laboratory in recent years, and fully consider the reservation of the power distribution system. And circuit maintenance and other issues. 6. Laboratory air-conditioning system The air-conditioning system not only controls the temperature and humidity of the laboratory, but also should cooperate with the laboratory ventilation system to truly and effectively ensure the effect of laboratory construction. 7. Laboratory fire-fighting system The laboratory's requirements for fire-fighting are higher than those of ordinary places. The laboratory design should adopt different fire-fighting measures in accordance with specific conditions to ensure the fire safety of the laboratory. 8. The pipes of the drainage system of the laboratory's water supply and drainage system should be resistant to acid and alkali corrosion and the melting of materials by organic reagents. PPR or other materials should be used instead of ordinary PVC pipes. At the same time, it should be based on the nature, flow, and discharge of sewage. The plan is determined according to the law and combined with outdoor drainage conditions. 9. Laboratory gas supply system The operation of many equipment in the laboratory requires a variety of gas supplies, and the safety of the gas cylinder room must be guaranteed. 10. Laboratory ventilation and exhaust system The design of the laboratory's air supply and exhaust system affects the entire environment and the health of laboratory personnel, and the operation and maintenance of laboratory equipment. 11. The choice of laboratory furniture The choice of laboratory furniture should first consider that it can fully meet the needs of the work, which mainly involves elements such as tabletop material, cabinet structure and material, and color matching. 12. Laboratory interior decoration details During laboratory decoration, do not adopt a large overall structure for the ceiling, which will cause hidden dangers to subsequent construction and maintenance. Floor-to-ceiling glass curtain wall design can be used on both sides of the visiting corridor or large instrument room, which is more transparent and bright, which is convenient for management and visit.

GET IN TOUCH WITH Us
recommended articles
Cobb Test Paper Absorption Tester GT-N07 - A Comprehensive Guide
The Cobb Test Paper Absorption Tester GT-N07 is an essential instrument for evaluating the water absorption properties of paper and paperboard materials. This test, commonly known as the Cobb method, helps determine how much water paper can absorb over a specified time under controlled conditions—crucial for assessing its suitability in printing, packaging, and coating applications.
Mask Testing Equipment: Everything You Need to Know
This article comprehensively introduces mask testing equipment, including its definition, application significance, core international testing standards, main equipment types and functional characteristics. It also puts forward a step-by-step selection guide and common selection misunderstandings, providing a reference for mask manufacturers, third-party testing institutions and regulatory departments to select appropriate testing equipment, so as to ensure mask product quality, pass international certification and protect user safety.
Why TDM Cut Test Machine GT-KC28 Is Needed in PPE Testing

Cut resistance is one of the most critical performance indicators in personal protective equipment (PPE) testing, directly affecting worker safety in high-risk industries such as metal processing, machinery manufacturing, and emergency rescue. The TDM Cut Test Machine GT-KC28 plays a vital role in accurately evaluating the cut resistance of PPE products, including gloves, protective clothing, footwear materials, composite materials, rubber, and industrial textiles.

By adopting high-precision force control systems, intelligent data processing, and stable transmission technology, the GT-KC28 TDM Cut Tester can accurately measure the critical cutting force of materials and ensure excellent repeatability and comparability of test results. Its user-friendly touch-screen operation, comprehensive data storage, USB data export, and built-in thermal printer greatly improve laboratory efficiency and data traceability.

The TDM Cut Test Machine GT-KC28 fully complies with major international and national standards such as ISO 13997, EN 388, ASTM F2992/F2992M, ANSI/ISEA 105, and GB 24541-2022, making it a reliable solution for PPE manufacturers, third-party testing laboratories, and research institutions. Through precise and standardized cut resistance testing, the GT-KC28 helps reduce industrial cutting injuries, supports PPE certification across global markets, and ensures that protective equipment delivers reliable safety performance in real-world applications.
What Are the ISTA Standard Tests and ISTA Testing Equipment?
ISTA (International Safe Transit Association) standard tests are globally recognized transportation packaging test procedures designed to evaluate the safety and reliability of products and their packaging throughout the logistics chain. By simulating real-world transportation conditions such as drops, vibration, impact, stacking, and compression, ISTA testing helps identify potential packaging weaknesses before products enter large-scale distribution. ISTA testing equipment—including drop testers, vibration testers, incline impact machines, and compression testers—plays a critical role in accurately reproducing these conditions under laboratory settings. Proper selection and use of ISTA-compliant equipment enable manufacturers to reduce transportation damage, lower return costs, enhance packaging design, and improve customer confidence in product quality and logistics safety.
PPE Testing Laboratory Equipment List
Setting up a PPE testing laboratory requires the right combination of instruments for safety footwear, gloves, protective clothing, masks and safety helmets. This guide explains the core testing equipment used in modern PPE laboratories, the standards they support, and the functions of each instrument, helping manufacturers, third-party laboratories and certification bodies choose a reliable and compliant testing setup.
Which Safety Footwear Test Method Is Suitable for You?
Selecting the correct safety footwear test method is essential for ensuring product durability, worker protection, and international compliance. Different tests evaluate different performance characteristics, including impact resistance, slip resistance, and outsole abrasion. This article explains how each testing method works, the applicable ISO, ASTM, DIN, and SATRA standards, and when manufacturers should use each test to improve product quality, reduce failures, and meet global certification requirements.
Sweating Guarded Hotplate GT-C98 Guide: Find the Right Testing Machine for Your Needs
The Sweating Guarded Hotplate GT-C98 is a professional instrument designed to evaluate the thermal resistance (Rct) and water-vapor resistance (Ret) of textiles and related materials. By simulating human skin heat dissipation and sweating under controlled conditions, it provides accurate and repeatable data for comfort and protective performance analysis. This guide introduces the testing principle, applicable international standards, industry applications, and key technical features to help users identify the right testing machine for product development, quality control, and research.
Leather Industry Innovations: GESTER at ACLE as a Footwear Testing Equipment Factory
The global leather and footwear industry is shifting toward prioritizing durability, material integrity, and functional excellence—driving demand for high-precision testing equipment. As a highlight of ACLE 2026 (All China Leather Exhibition), GESTER International Co., Ltd., a 25+ year footwear testing equipment factory, showcases innovative solutions tailored to this trend. Trusted by leading testing institutes like SGS, TUV, and Intertek, GESTER’s product lineup includes the Martindale Abrasion Tester (for surface durability), Tension Testing Machine (for mechanical properties), and Safety Shoe Cutting Tester—all compliant with ISO, ASTM, and EN standards. These instruments integrate automation (PLC systems) and data traceability to reduce human error, support ISO 9001 compliance, and streamline laboratory efficiency. With a global service network spanning 160+ countries, GESTER offers on-site installation, calibration, and software updates to ensure long-term usability. The article also outlines strategic procurement tips for manufacturers, emphasizing modular design, standard compatibility, and supplier track records. For leather and footwear brands seeking to enhance product reliability, avoid recalls, and stay competitive, GESTER’s ACLE 2026 innovations and end-to-end support provide a definitive quality assurance solution.
ISO 20345 vs ASTM F2413: Differences Between Safety Footwear Standards
ISO 20345 and ASTM F2413 are the two most recognized safety footwear standards used worldwide to evaluate protective footwear performance. Although both standards define minimum requirements for impact resistance and compression protection, differences in test energy levels, compression loads, marking systems, and hazard classifications can affect certification results. This article explains the key differences between ISO 20345 and ASTM F2413, helping footwear manufacturers, exporters, and quality control teams select the correct testing standard and improve compliance with international safety requirements.
Heat Contact Machine GT-C101-The Ultimate Selection Guide

The Heat Contact Machine GT-C101 is a specialized testing instrument designed for evaluating the heat resistance and thermal protective performance of gloves, protective clothing, and other heat-resistant materials used in high-temperature environments. In industries such as smelting, casting, welding, and glass manufacturing, workers are frequently exposed to intense heat, making accurate testing of contact heat resistance essential for ensuring safety and compliance.

GT-C101 simulates real working conditions by measuring heat transfer delay and thermal transmission under instant contact with high-temperature surfaces. Fully compliant with EN 407, EN 702, and ISO 12127-1 standards, this machine provides precise, repeatable data for manufacturers, laboratories, and research institutions. With high-temperature capability up to 500°C, advanced calorimetry, digital monitoring, and adjustable contact speed, the Heat Contact Machine GT-C101 is an indispensable tool for developing and certifying next-generation PPE and heat-insulation materials.
GESTER International Co., Ltd. gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059985379
Address:  No.15, Chifeng Road,Licheng Region, Quanzhou city of Fujian,PR China.
Customer service
detect