loading

PPE Testing Equipment Manufacturer | Safety Equipment Testing Machines | GESTER


Products

Introduction to applicable standards of mask filtration efficiency tester and national mask standards

In the context of the epidemic, the production of masks has become a hot topic of media discussion. Different standard classification of masks, such as FFP1-3 and KN95/KP95, as well as the differences in the definitions and tolerances of test conditions in various countries, make the test results of mask filtration efficiency different. When changing the particle mass concentration or particle size distribution, the test results between different standards also vary widely. The filtration efficiency of mass concentration depends on the large particles in the aerosol, and the transmittance of small particles will be significantly higher than the results calculated based on mass concentration. Even the data comparability within the EN149 standard will produce certain transmittance differences due to differences in particle size distribution and dust concentration, which will affect the results of mask grade classification. QINSUN G506 Mask Filtration Efficiency Tester can provide filtration efficiency tests in accordance with national standard GB2626, European standard EN149, American standard NIOSH (42CFR84) and ASTM F2100, etc., providing strong support for users' domestic and export business. The test bench will select the corresponding photometer mode to complete the measurement according to the standard requirements, and is equipped with two generators, oil and salt, to support the filtration efficiency test of masks and flat filter materials. National mask standards: Several main standards for Chinese masks are GB2626-2019 respiratory protection self-priming filter anti-particulate respirator, GB32610-2016 technical specifications for daily protective masks, YY0969-2013 disposable medical masks, YY0469-2011 medical surgical masks Technical requirements for masks and GB19083-2010 medical protective masks. According to the filtration efficiency of the masks, the masks are divided into three grades: 90 (KN90, KP90), 95 (KN95, KP95), and 100 (KN100, KP100). The number indicates the size of the filtration efficiency. The KN series is detected by sodium chloride particles, and the KP series is detected by oil particles. The revised version of the standard GB2626-2019 'Respiratory Protection Self-Priming Filtering Anti-Particulate Respirator' was officially released on December 31, 2019. The new standard adds requirements for respirator materials and leak detection methods for detachable parts of products. The test flow of this standard is 85L/min. The index requirements of breathing resistance are: the inspiratory resistance does not exceed 350pa, and the expiratory resistance does not exceed 250pa. The European Union's European Union (Conformite Europeenne, CE) certification standards for masks include BSEN140, BSEN14387, BSEN143, BSEN149, and BSEN136. Among them, BSEN149 is widely used and is a filter-type half mask that can protect against particles. According to the particle penetration rate tested, it is divided into P1 (FFP1), P2 (FFP2), P3 (FFP3) three levels, FFP1 low filter effect≥80%, FFP2 low filter effect≥94%, FFP3 low filter effect≥97%. The filtration efficiency of FFP2 masks is very close to that of medical protective masks, KN95 masks, and N95 masks. The test flow of this standard is 95L/min. EN149 contains a number of tests. The filtration efficiency test method of EN149 is similar to EN13274-7. EN 13274-7 tests the filtration efficiency of protective masks. The U.S. NIOSH standard classifies the filter material and filtration efficiency of masks, and this standard is highly recognized around the world. According to the filter material of the middle layer of the mask, it is divided into three types: N, R, and P series, each of which can be divided into three levels according to the filtration efficiency. N is used to protect non-oily suspended particles, usually non-oily particles refer to coal dust, cement dust, acid mist, microorganisms, etc. The droplets produced by speaking or coughing are not oily. In the current raging smog pollution, most of the suspended particles are non-oily. Oily particulate matter refers to oil fume, oil mist, asphalt fume, etc., such as oily particulate matter produced by cooking. R and P are used to protect non-oily and oily suspended particles. Compared with the R series, the P series has a relatively long use time. For the specific use time, please refer to the labels of different manufacturers. N95 masks are the filtration efficiency in the N series≥95% of the first-class masks are tested for the tightness of the wearer's face to ensure that the air can enter and exit through the mask when it is closely attached to the edge of the face. Only those who meet this test will be issued an N95 certification number. N95 masks are not equal to medical protective masks. Medical protective masks stipulate that the filtering effect of masks must meet the requirements of N95, and have surface moisture resistance and blood barrier capabilities. The ASTMF2100 standard is a medical standard that divides masks into three levels: low protection (Level1), medium protection (Level2) and high protection (Level3). The higher the level, the better the protection performance. Level1 and Level2 masks are usually called procedure masks; Level3 masks can be used in the operating room, also called surgical masks. When the chance of exposure to the virus is particularly high, a higher level of protection should be selected. Level 1 can block 95% of bacteria and particles, even if it only reaches low protection standards, it is enough to protect general community users; Level 2 and Level 3 (medium to high protection standards) require masks to block at least 98% of bacteria and particles, and the pressure difference is only It needs to be lower than 49.0Pa/cm, and the lower protection standard is looser, because it is difficult to achieve better protection while maintaining breathability. The main difference between the medium and high protection standards is that the high protection (Level 3) standard has higher requirements for the ability to block liquids.

Maintaining tensile tester manufacturers is not as easy as it may seem. You have to do plenty of important tasks. So cruel is the truth unless you've got a to help you.

For more tips and strategies on effective tensile tester manufacturers solutions, get your choice at GESTER Instruments.

GESTER International Co.,Limited’s mission is to provide you with an outstanding member/Customer benefit that helps you meet your organization’s objectives.

GET IN TOUCH WITH Us
recommended articles
What is the Safety Glove & Shoe Upper Cutting Tester GT-KC29
The Safety Glove & Shoe Upper Cutting Tester GT-KC29 is a high-precision testing instrument developed to measure the cut resistance performance of safety gloves and footwear uppers. In industrial and construction environments where sharp tools and metal edges pose significant injury risks, the GT-KC29 provides a reliable evaluation method by simulating real cutting motion. This tester meets EN 388 section 6.2, ISO 20344:2021 section 5.23, GB/T 20991 section 6.14, and other global standards, making it essential for PPE manufacturers, testing laboratories, and quality control departments. With automated operation, high repeatability, and multi-standard compliance, it helps companies improve product safety levels, enhance global competitiveness, and ensure superior protection for end users.
What Are the ISTA Standard Tests and ISTA Testing Equipment?
ISTA (International Safe Transit Association) standard tests are globally recognized transportation packaging test procedures designed to evaluate the safety and reliability of products and their packaging throughout the logistics chain. By simulating real-world transportation conditions such as drops, vibration, impact, stacking, and compression, ISTA testing helps identify potential packaging weaknesses before products enter large-scale distribution. ISTA testing equipment—including drop testers, vibration testers, incline impact machines, and compression testers—plays a critical role in accurately reproducing these conditions under laboratory settings. Proper selection and use of ISTA-compliant equipment enable manufacturers to reduce transportation damage, lower return costs, enhance packaging design, and improve customer confidence in product quality and logistics safety.
How to Find a Professional Safety Glove Testing Machine Manufacturer with CE Certification?
With the global PPE market’s rapid growth, choosing a professional CE-certified safety glove testing machine manufacturer is critical for data integrity and international compliance. This article explains why CE certification is non-negotiable (ensuring EU safety/quality standards), outlines essential test items (abrasion, cut, thermal protection per EN 388/EN 407), highlights core instruments (GESTER GT-KC28 TDM Cut Tester, GT-KC29 Cutting Tester, GT-C101 Heat Contact Machine), and details how to evaluate suppliers (20+ years of experience, partnerships with SGS/Bureau Veritas, ISO 9001 certification, after-sales support). It also covers the benefits of OEM/ODM capabilities for customized solutions. Ultimately, partnering with trusted manufacturers like GESTER ensures high-precision, compliant testing to protect workers and meet global market requirements.
Analyzing the Sweating Guarded Hotplate GT-C98 & Why it is Important
The Sweating Guarded Hotplate GT-C98 is a professional textile testing instrument designed to measure thermal resistance and evaporative resistance of fabrics, garments, and personal protective equipment (PPE). By simulating heat and moisture transfer from human skin, the instrument provides reliable data for evaluating thermal comfort, breathability, and moisture management properties. This article explores the working principle, key features, applications, and importance of the GT-C98, helping manufacturers, laboratories, and researchers improve textile product development and quality assurance.
What is the Safety Footwear Impact Tester & Why are They Important in Safety Shoes Testing
A Safety Footwear Impact Tester evaluates the impact resistance of safety shoes by striking the steel toe cap with 100J/200J kinetic energy, ensuring compliance with global standards (EN ISO 20344, ASTM F2412). It’s critical for verifying product protection, facilitating certification, and optimizing safety shoe design. GESTER Instruments offers reliable, user-friendly testers trusted by manufacturers and labs worldwide.
Sweating Guarded Hotplate GT-C98 Guide: Find the Right Testing Machine for Your Needs
The Sweating Guarded Hotplate GT-C98 is a professional instrument designed to evaluate the thermal resistance (Rct) and water-vapor resistance (Ret) of textiles and related materials. By simulating human skin heat dissipation and sweating under controlled conditions, it provides accurate and repeatable data for comfort and protective performance analysis. This guide introduces the testing principle, applicable international standards, industry applications, and key technical features to help users identify the right testing machine for product development, quality control, and research.
Looking for a Laboratory Protective Clothing Tester Supplier? Key Criteria to Consider
As global demand for high-performance PPE surges, selecting a qualified laboratory protective clothing tester supplier becomes critical for manufacturers and regulators. This article outlines core selection criteria: compliance with international standards (ISO, EN, ASTM), comprehensive protective gear tests (particle resistance, fluid barrier, thermal resistance, electrostatic safety), manufacturer qualifications (ISO 9001 certification, partnerships with SGS/TUV/Intertek), equipment precision (automation, modular design, data traceability), and end-to-end service (global support, calibration, customization). With 25+ years of experience, GESTER International delivers standards-aligned, high-precision testing instruments and integrated laboratory solutions, ensuring PPE meets rigorous safety requirements for medical, industrial, and chemical sectors. Explore how to choose a partner that safeguards worker safety through reliable testing.
GESTER's Success at Shoes & Leather - Vietnam 2025
GESTER successfully participated in Shoes & Leather Vietnam 2025 (July 9-11), showcasing cutting-edge footwear testing machines. Visitors explored equipment like the Bally Resistance Flexing Tester and Martindale Abrasion Tester, with many expressing strong collaboration interest. Learn more about GESTER’s innovative solutions for the footwear industry.
ISO 20344 Tester – Tested by ISO 20344 Standard
EN ISO 20344 is the core international test method standard for full-performance detection of safety footwear. This article systematically explains the full range of whole-shoe test items covered by the ISO 20344 standard, analyzes the core practical advantages of mandatory ISO 20344 testing for factories and laboratories, and matches a complete set of dedicated ISO 20344 testers one by one. It also sorts out mainstream associated safety footwear standards worldwide, providing one-stop standardized testing solutions for safety footwear manufacturers, third-party testing institutions and occupational safety supervision departments.
How to Choose Light Fastness Tester: Water-Cooled and Air-Cooled
Choosing between water-cooled and air-cooled light fastness testers depends on precision needs, budget, and application. Water-cooled testers (like GESTER GT-3000) offer superior spectral accuracy and stability for rigorous standards (e.g., automotive, coatings). Air-cooled models (like GESTER GT-D02A-1) provide energy efficiency and easier installation for routine QC. This guide compares cooling methods, features, and applications to help you select the optimal tester.
GESTER International Co., Ltd. gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059985379
Address:  Block 402,4th floor, f buliding, shengfulan business Center, no.577 jitai road, economic and  Technological development zone quanzhou of fujian.China.
Customer service
detect