loading

GESTER PPE Testing Equipment | Professional Safety Footwear Testing Equipment, Glove Testing Equipment, Protective Clothing Testing Equipment


Products

Introduction to applicable standards of mask filtration efficiency tester and national mask standards

In the context of the epidemic, the production of masks has become a hot topic of media discussion. Different standard classification of masks, such as FFP1-3 and KN95/KP95, as well as the differences in the definitions and tolerances of test conditions in various countries, make the test results of mask filtration efficiency different. When changing the particle mass concentration or particle size distribution, the test results between different standards also vary widely. The filtration efficiency of mass concentration depends on the large particles in the aerosol, and the transmittance of small particles will be significantly higher than the results calculated based on mass concentration. Even the data comparability within the EN149 standard will produce certain transmittance differences due to differences in particle size distribution and dust concentration, which will affect the results of mask grade classification. QINSUN G506 Mask Filtration Efficiency Tester can provide filtration efficiency tests in accordance with national standard GB2626, European standard EN149, American standard NIOSH (42CFR84) and ASTM F2100, etc., providing strong support for users' domestic and export business. The test bench will select the corresponding photometer mode to complete the measurement according to the standard requirements, and is equipped with two generators, oil and salt, to support the filtration efficiency test of masks and flat filter materials. National mask standards: Several main standards for Chinese masks are GB2626-2019 respiratory protection self-priming filter anti-particulate respirator, GB32610-2016 technical specifications for daily protective masks, YY0969-2013 disposable medical masks, YY0469-2011 medical surgical masks Technical requirements for masks and GB19083-2010 medical protective masks. According to the filtration efficiency of the masks, the masks are divided into three grades: 90 (KN90, KP90), 95 (KN95, KP95), and 100 (KN100, KP100). The number indicates the size of the filtration efficiency. The KN series is detected by sodium chloride particles, and the KP series is detected by oil particles. The revised version of the standard GB2626-2019 'Respiratory Protection Self-Priming Filtering Anti-Particulate Respirator' was officially released on December 31, 2019. The new standard adds requirements for respirator materials and leak detection methods for detachable parts of products. The test flow of this standard is 85L/min. The index requirements of breathing resistance are: the inspiratory resistance does not exceed 350pa, and the expiratory resistance does not exceed 250pa. The European Union's European Union (Conformite Europeenne, CE) certification standards for masks include BSEN140, BSEN14387, BSEN143, BSEN149, and BSEN136. Among them, BSEN149 is widely used and is a filter-type half mask that can protect against particles. According to the particle penetration rate tested, it is divided into P1 (FFP1), P2 (FFP2), P3 (FFP3) three levels, FFP1 low filter effect≥80%, FFP2 low filter effect≥94%, FFP3 low filter effect≥97%. The filtration efficiency of FFP2 masks is very close to that of medical protective masks, KN95 masks, and N95 masks. The test flow of this standard is 95L/min. EN149 contains a number of tests. The filtration efficiency test method of EN149 is similar to EN13274-7. EN 13274-7 tests the filtration efficiency of protective masks. The U.S. NIOSH standard classifies the filter material and filtration efficiency of masks, and this standard is highly recognized around the world. According to the filter material of the middle layer of the mask, it is divided into three types: N, R, and P series, each of which can be divided into three levels according to the filtration efficiency. N is used to protect non-oily suspended particles, usually non-oily particles refer to coal dust, cement dust, acid mist, microorganisms, etc. The droplets produced by speaking or coughing are not oily. In the current raging smog pollution, most of the suspended particles are non-oily. Oily particulate matter refers to oil fume, oil mist, asphalt fume, etc., such as oily particulate matter produced by cooking. R and P are used to protect non-oily and oily suspended particles. Compared with the R series, the P series has a relatively long use time. For the specific use time, please refer to the labels of different manufacturers. N95 masks are the filtration efficiency in the N series≥95% of the first-class masks are tested for the tightness of the wearer's face to ensure that the air can enter and exit through the mask when it is closely attached to the edge of the face. Only those who meet this test will be issued an N95 certification number. N95 masks are not equal to medical protective masks. Medical protective masks stipulate that the filtering effect of masks must meet the requirements of N95, and have surface moisture resistance and blood barrier capabilities. The ASTMF2100 standard is a medical standard that divides masks into three levels: low protection (Level1), medium protection (Level2) and high protection (Level3). The higher the level, the better the protection performance. Level1 and Level2 masks are usually called procedure masks; Level3 masks can be used in the operating room, also called surgical masks. When the chance of exposure to the virus is particularly high, a higher level of protection should be selected. Level 1 can block 95% of bacteria and particles, even if it only reaches low protection standards, it is enough to protect general community users; Level 2 and Level 3 (medium to high protection standards) require masks to block at least 98% of bacteria and particles, and the pressure difference is only It needs to be lower than 49.0Pa/cm, and the lower protection standard is looser, because it is difficult to achieve better protection while maintaining breathability. The main difference between the medium and high protection standards is that the high protection (Level 3) standard has higher requirements for the ability to block liquids.

Maintaining tensile tester manufacturers is not as easy as it may seem. You have to do plenty of important tasks. So cruel is the truth unless you've got a to help you.

For more tips and strategies on effective tensile tester manufacturers solutions, get your choice at GESTER Instruments.

GESTER International Co.,Limited’s mission is to provide you with an outstanding member/Customer benefit that helps you meet your organization’s objectives.

GET IN TOUCH WITH Us
recommended articles
How to Know the Fabric Shrinkage Test for Your Projects
Master fabric shrinkage testing with this definitive guide. Understand causes of shrinkage, industry standards (ISO, GB, AATCC), step-by-step testing methods using Wascator equipment, and strategies to minimize shrinkage for superior garment quality and customer satisfaction.
Mask Testing Equipment: Everything You Need to Know
This article comprehensively introduces mask testing equipment, including its definition, application significance, core international testing standards, main equipment types and functional characteristics. It also puts forward a step-by-step selection guide and common selection misunderstandings, providing a reference for mask manufacturers, third-party testing institutions and regulatory departments to select appropriate testing equipment, so as to ensure mask product quality, pass international certification and protect user safety.
Understanding Universal Tensile Testing machine: Feature, Operation
Discover how universal testing machines perform tensile, compression, bending, and peel tests on metals, plastics, rubber, and composites. Features include servo motors, 0.001mm resolution, RS232 data, and safety systems. Step-by-step operation guide included.
Safety Footwear Test Explained: Compression and Puncture Tester
This article fully explains the working principle, applicable international standards, test advantages and application scope of safety footwear compression and puncture tester GT-KB12A. It covers core protective performance testing of safety shoe toecap and sole steel plate, complies with GB, ISO, EN, ASTM and other global standards, and serves manufacturers, third-party labs and safety footwear R&D institutions for quality control .
Why GESTER Ranks as a Leading TPP Thermal Protective Performance Tester Exporter
As a trusted leading TPP Thermal Protective Performance Tester exporter, GESTER International Co., Ltd. brings 25+ years of R&D and manufacturing expertise to PPE safety testing. Our flagship GT-RC02 series TPP testers feature advanced dual-source thermal simulation, high-sensitivity sensors, and full digital automation—delivering precise, repeatable data to evaluate thermal protection for firefighter and industrial protective clothing. Fully compliant with global standards (NFPA 1971, EN 469, ISO), GESTER’s equipment is trusted by SGS, Intertek, and top testing institutes worldwide. Backed by ISO 9001 certification, global service in 160+ countries, and professional calibration support, we empower manufacturers and labs to meet stringent safety regulations and ensure life-saving thermal protection. Discover tailored TPP testing solutions for PPE excellence at GESTER.
Glove Tester: Key Standards EN 388 & EN 407
Protective glove testing is the core link to verify hand safety protection performance for industrial PPE. This article focuses on the two most authoritative EU mandatory standards EN 388 and EN 407, elaborates on standardized test necessity, complete test items, professional supporting glove testers, result rating rules, and the differences between mechanical risk testing and thermal risk testing. It provides one-stop compliant testing reference for glove manufacturers, third-party testing labs, and safety supervision institutions to meet global CE certification and workplace safety production requirements.
Understanding the Color Fastness To Washing Testing Machine GT-D07
The GESTER GT-D07 Color Fastness To Washing Testing Machine is designed to evaluate the color durability of dyed fabrics under washing and dry-cleaning conditions. By simulating real washing processes, it helps determine how resistant a fabric is to fading and staining, ensuring consistency, reliability, and compliance with international standards. With stainless-steel construction, safety features, and precise temperature and timing control, the GT-D07 provides an efficient and standardized testing solution for textile manufacturers worldwide.
How to Improve Plastic Film Drop Dart Impact Strength
Discover actionable strategies to enhance the drop dart impact strength of plastic films for packaging, agriculture, and construction. Learn how material selection, additives, processing, and rigorous ASTM/ISO drop dart impact testing ensure product durability and prevent failure.
Analysis of Pilling Influencing Factors and Testing Methods
Pilling testing plays a vital role in textile quality control, helping manufacturers evaluate and improve the wear performance of fabrics. Through the use of advanced instruments like ICI Pilling Box Test Method (GT-C18) , Martindale Abrasion Test Method (GT-C13B) , and Random Tumble Pilling Test Method (GT-C19A) , laboratories can conduct precise and standardized assessments, ensuring that final textile products deliver superior appearance, comfort, and longevity.
According to ASTM D642 Standard: Detailed Box Compression Strength Tester GT-N02A
The ASTM D642 standard defines the test method for determining the compressive resistance of shipping containers, like corrugated boxes, when faced with static compressive forces. This article details the test procedure and introduces the GESTER GT-N02A and GT-N02B Box Compression Testers, which are fully compliant with ASTM D642, ISO 12048, and TAPPI T804. These versatile machines perform destructive strength tests, constant value tests, and simulated long-term stacking tests to ensure your pac
Quanzhou Gester International Co.,Ltd gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.