loading

Gester Instruments | Professional Glove, Mask, Safety Helmet, Protective Clothing & Footwear Testing Equipment Manufacturer Since 1997


Products
Test Standard

Performance testing and analysis of lead protective clothing

Roentgen has discovered X-rays for more than 100 years, but conventional imaging has been the focus of development in the field of radiology for a long time. Only radiologists and technicians are radiologists, and other personnel rarely come into contact with X-rays. After the 1990s, with the improvement of radiological equipment and the accumulation of medical experience, various treatments carried out under the guidance of X-rays, such as: heart, nerve, vascular interventional surgery and ERCP techniques such as local anesthesia, minimally invasive surgery, The advantages of high accuracy, less pain, and quick recovery are favored by doctors and patients. The feature of this type of operation is that the doctor needs to operate near the patient's table in the computer room, and is inevitably exposed to X-ray radiation. Yu Peng reported that the dose rate can reach 7.69 mGy/h when the staff position does not use various protective devices [1], and Zhao Zhongqing reported that the maximum dose rate on the surface of the arm of the cardiac intervention staff can reach 0.35 mGy/h. Take Nanjing Gulou Hospital as an example. As of the end of March 2009, there are more than 180 radiologists in the hospital, involving doctors and nurses in many clinical departments such as radiology, heart, nerve, digestion, vascular, orthopedics and general surgery. And other related operators. Long-term fluoroscopy and filming have made the radiation protection of people exposed to such rays a difficult point in current radiation protection. In addition, with the popularization of radiation knowledge, patients have higher and higher requirements for shielding protection, and hospitals are required to provide safe and effective body protection during X-ray examination and treatment. In addition to minimizing the time of exposure to X-rays and keeping a safe distance from X-ray radiation sources, the personal protection of medical staff and patients is mainly to wear lead protective clothing to achieve shielding protection. Therefore, the performance of lead protective clothing is important for medical staff. And patient safety is of great significance. 1 Types of lead protective clothing In radiological diagnosis and treatment, lead protective clothing can effectively resist the unnecessary damage of X-rays to important organs of the human body. Its protective effect is related to the energy of the rays, and the shielding efficiency is 90% to 95%. According to the different key protection parts, lead protective clothing includes one-piece lead clothing, lead tops, lead skirts, lead aprons, lead caps, lead collars, etc., which are used to protect the whole body, chest and abdomen, reproductive organs, lower limbs, and head. And thyroid and other important parts. The protective performance of lead protective clothing is expressed by lead equivalent (mmPb), that is, lead is used as a comparative standard, and the protective effect is expressed by the thickness of lead with the same shielding effect. Usually the front part of the one-piece lead garment is 1.0 mmPb and the back is 0.25 mmPb; the lead skirt is 0.35 mmPb; the lead collar and the lead cap are 0.35 mmPb. 2 Correct use and storage of lead protective clothing. Protective clothing should not be simply stacked when stored. Wrinkles and indentations should be avoided. When hanging the lead clothing, pay attention to the balance of the shoulders. The lead hanger should be careful not to have sharp edges to avoid scratching the lead clothing. If there are blood stains and other dirt on the surface of the lead clothes, they must be cleaned up in time. Neutral soapy water and clean water can be used, and chemical detergents should not be used as much as possible. Wipe them with a soft cloth and hang them to dry. 3 Elimination standard of lead protective clothing. Lead protective clothing meets the corresponding national standards in terms of lead equivalent, weight and material integrity when leaving the factory. However, due to frequent use or improper storage, common damages include the following aspects: fabric damage, containing The lead material is exposed; the seams are opened to form cracks; there are holes and cracks on the surface of the material; the material hardens and cannot be worn; due to long-term wear and suspension, the lead layer breaks from the shoulders and falls off to the hem; the lead clothes buckle is damaged, Unable to wear tightly; improper maintenance methods after the lead clothing is damaged cause the lead layer to leak; long-term use causes the upper part of the protective clothing to become thinner and the lead equivalent decreases. Typical normal images and various unqualified images are shown in Figure 3-8. In order to ensure the protective effect of lead protective clothing, the damage must be eliminated to a certain degree. 4 Lead protective clothing detection method (1) Number each lead protective clothing, and use the first letter combination of the English name of each department as the identification (such as: Radiology-RD, Intervention Room-DSA, Cardiology-CR, Digestion Section-ERCP, operating room-OR), the suffix number is numbered, this method number is clear, easy to identify and find, and then spray the number on the protective clothing by spray paint. Finally, a database of protective clothing is compiled, including types, departments, numbers, specifications, etc., as well as each test time, test results, and processing methods. (2) Visually inspect the appearance to see if the lead-containing parts of the main body of the protective clothing are obviously damaged, such as cracks, cavities, creases, etc., whether the lead-free parts such as straps and clothes buckles are damaged. Visually unqualified protective clothing should Repair in time. (3) Perform a quick fluoroscopy inspection on the lead protective clothing on the PHILIPS TD digital gastrointestinal machine. In order to ensure the detection effect, the bed surface of the digital gastrointestinal machine is thoroughly cleaned before the detection to remove image background artifacts. Use manual parameter setting and low dose, do not use automatic brightness control, otherwise the device will automatically increase KV and tube current to avoid unnecessary radiation and tube load. Unfold the lead clothes and spread them flat on the bed without any wrinkles. Move the bed surface and lead garment to ensure that every detail is imaged under X-ray. The protected area on the image appears brown, while the damage, seams, and adhesives appear bright. (4) Use 100 kV for the damaged protective clothing to take pictures under automatic exposure conditions, save the images, measure and record the size and area of u200bu200bthe damaged part and register it in the database. (5) Through the use of perspective and filming, lead protective clothing can be found from small holes to large cracks, which is a simple and effective method to detect protective clothing.

In the present growing world of emerging technology, the has demanding operation in various sectors like tensile tester manufacturers, tensile tester manufacturers, tensile tester manufacturers and many other industries at tensile tester manufacturers levels of manufacturing and designing.

To live healthy, you need to eat healthy; to eat healthy, you need to think healthy; to think healthy, you need to read health; to read healthy, you need to follow GESTER Instruments.

textile testing equipment has a great positive reflects from our dear customers.

GET IN TOUCH WITH Us
recommended articles
How to Improve the Accuracy of a Martindale Tester
Ensuring the accuracy of your Martindale abrasion and pilling tester is critical for reliable textile quality control. This guide details essential steps, from precise sample preparation and correct machine operation to routine maintenance. We also explore how advanced testers, like the GESTER model with its dual-servo drive and tool-free operation, are engineered to eliminate common sources of error and enhance testing precision for superior results.
Mask Testing Equipment: Everything You Need to Know
This article comprehensively introduces mask testing equipment, including its definition, application significance, core international testing standards, main equipment types and functional characteristics. It also puts forward a step-by-step selection guide and common selection misunderstandings, providing a reference for mask manufacturers, third-party testing institutions and regulatory departments to select appropriate testing equipment, so as to ensure mask product quality, pass international certification and protect user safety.
Top Features of a Certified TDM Cut Resistance Tester Supplier for Laboratory Use
The demand for precise PPE safety testing has surged with the evolution of protective gear, making TDM (Tomodynamometer) cut resistance testing a critical process for evaluating protective gloves and industrial textiles. This article details the top features of a certified TDM cut resistance tester supplier for laboratory use, including compliance with international standards (EN 388, ISO 13997, ASTM F2992), high-precision mechanical engineering, automated workflows, robust data management, and integrated safety features. It highlights GESTER International Co., Ltd.—a 20+ year experienced manufacturer with ISO 9001 certification and partnerships with SGS, Intertek, and TUV—as a leading supplier, offering the GT-KC28 TDM Cut Test Machine and comprehensive services (on-site installation, calibration, global technical support). For laboratories seeking reliable, standard-compliant testing solutions to validate PPE safety claims, this article provides actionable insights into strategic procurement. Visit https://www.gesterinstruments.com/ for more technical specifications and PPE testing solutions.
What is the Use of Air Permeability Tester?
An air permeability tester measures how easily air passes through textiles, nonwovens, and other materials, directly impacting comfort (heat/moisture management) and performance (wind resistance, filtration). This guide explains how digital testers work using pressurized airflow, details step-by-step testing procedures (including nozzle selection), and covers key applications in apparel, medical, automotive, and industrial sectors. Explore compliant standards (ISO 9237, ASTM D737, GB/T 5453) and
Everything You Need to Know About Programmable Temperature Humidity Chamber
A Programmable Temperature Humidity Chamber simulates environmental conditions to test product durability, stability (like shelf life & ageing), and performance across materials, electronics, automotive parts, food, and pharmaceuticals. This guide explains its five core systems (Control, Refrigeration, Heating, Humidity, Air Circulation) and their functions for precise testing.
How to Choose the Right Safety Shoes Testing Equipment Supplier?
Safety shoes are essential personal protective equipment (PPE) in high-risk industries. To ensure compliance with international standards such as EN ISO 20345 and ASTM F2413, professional testing equipment is required. This article explains common safety shoes test items, corresponding testing machines, and how to choose a reliable safety shoes testing machine supplier. It also analyzes key factors such as technical capability, standard compliance, equipment stability, and cost performance to help enterprises build a strong quality control system and enhance global competitiveness.
How to Choose Light Fastness Tester: Water-Cooled and Air-Cooled
Choosing between water-cooled and air-cooled light fastness testers depends on precision needs, budget, and application. Water-cooled testers (like GESTER GT-3000) offer superior spectral accuracy and stability for rigorous standards (e.g., automotive, coatings). Air-cooled models (like GESTER GT-D02A-1) provide energy efficiency and easier installation for routine QC. This guide compares cooling methods, features, and applications to help you select the optimal tester.
Sweating Guarded Hotplate GT-C98 Guide: Find the Right Testing Machine for Your Needs
The Sweating Guarded Hotplate GT-C98 is a professional instrument designed to evaluate the thermal resistance (Rct) and water-vapor resistance (Ret) of textiles and related materials. By simulating human skin heat dissipation and sweating under controlled conditions, it provides accurate and repeatable data for comfort and protective performance analysis. This guide introduces the testing principle, applicable international standards, industry applications, and key technical features to help users identify the right testing machine for product development, quality control, and research.
Everything You Need to Know About the Hydrostatic Head Tester
A hydrostatic head tester evaluates the waterproof capability of textiles, automotive interiors, and industrial materials. This guide covers its working principle, core components, global test standards (ISO, AATCC, EN), and a detailed testing procedure to ensure accurate results.
Installation Training for the Incline Impact Tester GT-N49
Our expert team provides comprehensive on-site installation and training for the Incline Impact Tester GT-N49. This critical packaging testing equipment simulates real-world impacts during handling, transport, and stacking to evaluate product damage resistance. Learn about its key features like flexible moving plates, height adjustment, pneumatic angle control, and remote operation safety. Our service ensures proper setup, operational mastery, maintenance guidance, and troubleshooting support fo
no data
Quanzhou Gester International Co.,Ltd gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059985379
Address:  Block 402,4th floor, f buliding, shengfulan business Center, no.577 jitai road, economic and  Technological development zone quanzhou of fujian.China.
Customer service
detect