Medical protective masks refer to self-priming filter dust-proof medical protective masks that can filter particles in the air and block droplets, blood, body fluids, secretions, etc. This is a mask that can prevent infections caused by airborne infectious agents with a diameter of ≤5μmg or close (≤1m) contact with droplet-borne diseases. The main physical properties of medical protective masks include: basic mask requirements, mask belt, filtration efficiency, airflow resistance, synthetic blood penetration, and adhesion. 1. Sample source and product standards for sampling 1.1 Quantity and distribution of samples received This national sampling received a total of 8 batches of inspection products. The sampling sources of samples and the distribution of production enterprises are shown in Table 1. 1.2 Product standard situation This inspection involves a total of 6 production enterprises, of which the product implementation standards of 2 enterprises in Henan are GB 19083-2010 [1], and the standards of 2 enterprises in Guizhou and Shanghai The product implementation standard is the YZB standard, and the products of the two enterprises in Guangdong and Sichuan implement product technical requirements. Two of the company registered product standards added the item of 'loading filter efficiency2. Physical performance inspection 2.1 Inspection items 2.1.1 Basic requirements for masks 2.1.1.1 Inspection method: visual inspection. 2.1.1.2 Equipment: None. 2.1.2 Mask belt 2.1.2.1 Inspection method: Measure by visual inspection and tensile test device. 2.1.2.2 Equipment: heavy hammer. 2.1.3 Filtration efficiency 2.1.3.1 Inspection method: Sodium chloride aerosol or similar solid aerosol in an environment with a relative humidity of 30%±10% and a temperature of 25°C±5°C should be used. Median diameter (CMD): 0.075μm±0.020μm; geometric standard deviation of particle distribution: ≤1.86; concentration: ≤200 mg/m3] for testing. The air flow is set to 15 L/min±2 L/min, and the cross-sectional area through which the air flows is 100 cm2. 2.1.3.2 Equipment: TSI-8130 material filterability tester; 2.1.4 Air flow resistance 2.1.4.1 Inspection method: the same 2.1.3.2.1.4.2 Equipment: TSI-8130 material filterability tester. 2.1.5 Synthetic blood penetration 2.1.5.1 Inspection method: (1) Pretreatment: Pretreat the mask sample in an environmental test box at a temperature of 21°C±5°C and a relative humidity of 85%±5% for 4 hours. The mask sample is taken out of the environmental box for testing within 1 min; (2) Talc powder needs to be sprinkled on the inner surface of the mask to increase the visibility of the droplets; (3) The sample is taken out of the pretreatment chamber, positioned and fixed on the sample The fixed device allows the synthetic blood to be sprayed onto the target area. Place the spray head at (300±10) mm away from the sample target area; (4) Spray the synthetic blood to the medical mask sample. Ensure that the synthetic blood is sprayed to the target area of u200bu200bthe mask. The test is carried out within 60 s after the sample is taken out of the pretreatment chamber; (5) Check the observation surface of the sample (10 ± 1) s after the synthetic blood is sprayed to the target area. Under proper lighting conditions, pay attention to whether there is synthetic blood on the observation surface of the mask or can show signs of synthetic blood. 2.1.5.2 Equipment: LYF-227 synthetic blood penetration tester for medical masks. 2.1.6 Tightness 2.1.6.1 Inspection method (1) The equipment self-checks the number of particles in the air. After passing, the test is started. (2) Select 10 subjects, half male and half, head shape conforming to GB/T2428-1998 [2] Chinese head shape series. The male shaves his beard. Wear a mask according to the instructions for use. Check before the test, including that the mask has no tendency to move, the mask strap should not be too loose or too tight, the nose clip fits the bridge of the nose, and the surrounding area should not leak. No further adjustments are allowed during the test process. The subjects were required to do the following 6 prescribed actions, each for 1 min: (a) Normal breathing-standing posture, normal breathing rate, no speech. (B) Take a deep breath-stand up, breathe slowly and deeply, and be careful not to exhale excessively. (C) Turn your head left and right-in a standing posture, slowly turn your head to one side to the extreme position and then turn to the other side. There should be inhalation at each extreme position. (D) Move your head up and down-slowly lower your head, then slowly raise your head, there should be an inhalation action at the limit position of the head. (E) Speak-speak loudly and slowly. Ask the subject to count down from 100 or read an article. (F) Normal breathing-same as (a). Select 10 subjects, wear masks according to the instruction manual, perform 6 prescribed actions, and test according to the following methods. At least 8 subjects should have a total fitness factor that meets the requirements. 2.1.6.2 Equipment: TSI-N95-COMPANION adhesion tester. 2.2 Inspection results The physical performance inspection results are shown in Table 2. 2.3 Judgment principles All inspection items are judged according to product registration standards or technical requirements. 3. Analysis of non-conformance items 3.1 Filtration efficiency 3.1.1 Features and functions Filtration efficiency refers to the percentage of particulate matter in the air filtered by a mask under specified conditions; medical protective masks can filter particulate matter in the air, blocking droplets, blood, and body fluids , Secretions, etc. 3.1.2 Importance Filter efficiency is the fundamental factor that determines the protective effect of masks. 3.1.3 Reason analysis The filtration efficiency of raw materials is not up to standard, and the quality is problematic. 3.1.4 Suggestions for improvement It is recommended that the manufacturer should strictly control the filtration efficiency of the raw materials of the product. 3.2 Adhesion 3.2.1 Features and functions Adhesion of a mask refers to the degree of adhesion between the periphery of the mask and the face of a specific user, and is a barrier item to prevent the entry of harmful substances. 3.2.2 Importance If the protective mask cannot be closely attached to the user's face, harmful substances in the air will enter the mask from the leak and cause harm to the human respiratory tract. 3.2.3 Cause analysis (1) The material of the nose clip is too soft, the position of the nose clip leaks, and the mask does not fit well with the human nose;

It isn't just about being on textile testing equipment anymore–it's about maximizing the potential of the platform of manufacturing.

Deliver value to our customers by providing the most reliable and efficient products as textile testing equipment.

GESTER International Co.,Limited expects to reach the desired profits in the first year and does not anticipate serious cash flow problems.

GET IN TOUCH WITH Us
recommended articles
Understanding Universal Tensile Testing machine: Feature, Operation
Discover how universal testing machines perform tensile, compression, bending, and peel tests on metals, plastics, rubber, and composites. Features include servo motors, 0.001mm resolution, RS232 data, and safety systems. Step-by-step operation guide included.
Leather Physical Properties Testing Guide
This guide details the 9 critical physical property tests essential for assessing leather quality: Tensile Strength, Tear Strength, Abrasion Resistance, Thickness, Water Vapor Permeability, Water Resistance, Shrinkage Temperature, Color Fastness to Friction, and Bending Strength. It covers the testing scope (natural leather, synthetic leather, finished products, semi-finished goods) and introduces specialized testing equipment required for each method (e.g., Universal Testing Machine, Elmendorf
How to Improve Plastic Film Drop Dart Impact Strength
Discover actionable strategies to enhance the drop dart impact strength of plastic films for packaging, agriculture, and construction. Learn how material selection, additives, processing, and rigorous ASTM/ISO drop dart impact testing ensure product durability and prevent failure.
How to Choose Light Fastness Tester: Water-Cooled and Air-Cooled
Choosing between water-cooled and air-cooled light fastness testers depends on precision needs, budget, and application. Water-cooled testers (like GESTER GT-3000) offer superior spectral accuracy and stability for rigorous standards (e.g., automotive, coatings). Air-cooled models (like GESTER GT-D02A-1) provide energy efficiency and easier installation for routine QC. This guide compares cooling methods, features, and applications to help you select the optimal tester.
What is the Safety Footwear Impact Tester & Why are They Important in Safety Shoes Testing
A Safety Footwear Impact Tester evaluates the impact resistance of safety shoes by striking the steel toe cap with 100J/200J kinetic energy, ensuring compliance with global standards (EN ISO 20344, ASTM F2412). It’s critical for verifying product protection, facilitating certification, and optimizing safety shoe design. GESTER Instruments offers reliable, user-friendly testers trusted by manufacturers and labs worldwide.
Elmendorf Tearing Strength Tester GT-C11A You Should Know
The Elmendorf Tearing Strength Tester GT-C11A is a pivotal instrument for evaluating the tearing resistance of various materials, including textiles, non-wovens, paper, and films. Utilizing the proven pendulum method, it delivers precise, repeatable data crucial for quality assurance, product development, and compliance with international standards like ASTM and ISO. This article explores its working principle, key features such as automated testing and pneumatic clamping, and its wide-ranging applications across multiple industries, highlighting why the GT-C11A is a trusted choice for professionals seeking reliable and efficient material performance analysis.
Everything You Need to Know About the Hydrostatic Head Tester
A hydrostatic head tester evaluates the waterproof capability of textiles, automotive interiors, and industrial materials. This guide covers its working principle, core components, global test standards (ISO, AATCC, EN), and a detailed testing procedure to ensure accurate results.
What Are the Test Methods for Fabric Bursting Strength?
Fabric bursting strength measures resistance to rupture under concentrated load. Three primary test methods are used:

Ball Burst Method (ASTM D3787): Steel ball penetration for textiles/films using testers like GT-C02-2.

Hydraulic Method (ISO 13938.1): Fluid pressure on rubber diaphragm for industrial fabrics via GT-C12A.

Pneumatic Method (ISO 13938.2): Compressed air for breathable materials tested with GT-C12B.
Results are influenced by raw materials, yarn properties,
GESTER: China Top PPE Testing Equipment Company Leading Global Safety Standards
Since 1997, GESTER International Co., Ltd has emerged as China’s top PPE testing equipment company, with 25+ years of R&D experience in high-precision testing instruments. Serving clients in over 160 countries and partnering with global leaders like SGS, Intertek, and TUV, GESTER aligns its products with international standards (ISO, ASTM, EN, GB) to ensure reliable PPE performance. Highlighted by the GT-RC02B TPP Thermal Protection Tester—capable of simulating extreme thermal environments and calculating critical safety metrics like TPP values and escape time—and the GT-KC28 TDM Cut Test Machine, GESTER’s portfolio covers thermal protection, cut resistance, footwear testing, and more. The company offers comprehensive support, including ISO 17025/NFPA-aligned calibration, on-site installation, and staff training, empowering PPE manufacturers and testing laboratories to meet stringent global regulations, prevent workplace injuries, and accelerate market access. As a leader in global safety standards, GESTER combines technical precision, user-centric design, and lifecycle service to deliver tailored solutions for high-risk industries worldwide. Visit https://www.gesterinstruments.com/ for full product details.
Cobb Test Paper Absorption Tester GT-N07 - A Comprehensive Guide
The Cobb Test Paper Absorption Tester GT-N07 is an essential instrument for evaluating the water absorption properties of paper and paperboard materials. This test, commonly known as the Cobb method, helps determine how much water paper can absorb over a specified time under controlled conditions—crucial for assessing its suitability in printing, packaging, and coating applications.
no data
Quanzhou Gester International Co.,Ltd gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.