loading

GESTER PPE Testing Equipment | Professional Safety Footwear Testing Equipment, Glove Testing Equipment, Protective Clothing Testing Equipment


Products

Research on the Respiratory Resistance of Haze Respirators

In response to frequent haze weather, people are paying more and more attention to the protection of PM2.5, and it has become a habit to wear anti-haze masks. How to improve the wearing comfort of anti-haze masks and prolong the use time of the masks, to ensure that the masks will not feel stuffy for a long time, breathe easily, and also ensure that the filtration efficiency of PM2.5 meets the requirements. Important research content. Under normal circumstances, the filtration efficiency of masks will not decrease with use. On the contrary, as fine particles are adsorbed on the fabric, the filtration efficiency of masks may increase with the length of use. Therefore, this article focuses on the changes in the respiratory resistance of anti-haze masks with the duration of use. This study conducted an experimental study on 8 types of PM2.5 protective masks that are popular on the market, basically covering the existing types of anti-haze masks on the market, and selected 24 wearers used it continuously while sitting still, and tested the change of respiratory resistance every 1 hour. At the same time, the subjective breathing experience of each wearer was interviewed and recorded, and the breathing of the mask was comprehensively evaluated from the two aspects of the test results and the subjective feelings of the wearers. The relationship between the resistance and the duration of use is a reference for improving the breathing comfort of haze masks in the future. 1  The experimental method was tested under the outdoor environmental conditions where the air pollution is light pollution, the air quality index (AQI) is 124 and moderate pollution, and the AQI index is 163. The test bench is set up in strict accordance with the requirements of the respiratory resistance test standard in GB 2626-2006 'Respiratory Protective Equipment-Self-priming Filtered Anti-Particulate Respirator'. In the experiment, the 8386 multi-parameter ventilation meter is used to detect the pressure, which has high accuracy. The specific parameters of the experimental anti-haze masks are shown in Table 1. The outdoor test in the laboratory adopts the real breathing mode. After the testers breathe freely for 1 hour, the respiratory resistance value of the mask is tested. Each type of mask is tested for the respiratory resistance value of 3 masks at a time, and the average value of the 3 results is taken for continuous testing. 6 times. 2  The effect of external resistance on human breathing comfort The vacuum in the mask during inhalation (peak negative pressure) and the residual pressure during expiration (peak positive pressure) are called the external resistance of respiratory protective equipment. Excessive respiratory resistance can easily cause respiratory fatigue. Under mild physical load, the maximum fluctuation of oral pressure during breathing caused by the additional resistance of respiratory protective equipment does not exceed 7.5 cm H2O, or the increased breathing work per liter of ventilation does not exceed 0.05 (kg?m)/h, then more than 90% The user will not feel uncomfortable breathing. It is generally believed that external respiratory resistance will not cause cardiovascular and metabolic changes, but the air-supply mask can cause rapid changes in heart rate due to excessive weight. Therefore, when making and designing masks, we must consider the breathing resistance value of the mask, whether it will cause human breathing discomfort, and avoid excessive initial resistance of the mask or excessive increase of the resistance of the mask, which affects the use of the mask. The influencing factors of the external respiratory resistance are: ① The greater the total resistance value of the respiratory resistance, the more severe the respiratory discomfort. ②The proportional relationship of respiratory air resistance. Under mild physical load, the inhalation resistance component has a greater impact on the sense of respiratory discomfort; under severe physical load, the exhalation resistance may have a greater impact. ③Physical load can aggravate the impact of external respiratory resistance and increase the threshold of breathing discomfort. Heavy physical load and high temperature environment can aggravate the impact of external resistance. The interaction between them is 'additive'. ④The individual difference is significant, and the tolerance of women is worse than that of men. The laboratory is carried out under the condition of no physical load, and the influence of the above factors on the experimental results can be ignored. Personal protective masks use human breathing power (generally 30-50 Pa) as the purification power to purify the atmospheric environment to meet the human body's demand for clean air, and have low resistance characteristics relative to the mechanical power in the building environment. According to the GB 2626-2006 'Respiratory Protective Equipment-Self-priming Filtering Anti-Particulate Respirator' standard, the total resistance of various masks in inhalation should not be greater than 350 Pa, and the total resistance of exhalation should not be greater than 250 Pa. In the test, the inspiratory resistance is 350 Pa, and the exhalation resistance is 250 Pa as the pressure value at the end of the life of the mask. The test results of the initial respiratory resistance of the 8 masks are shown in Table 1. 3 Experimental results and analysis 3.1 The breathing of the wearer Among the 24 mask wearers in the experience experiment, 4 of them wore masks without breathing valve and then with breathing valve. During the 6 hours of the experimental test, almost all testers were able to adapt to the breathing resistance of the mask. There were no symptoms such as shortness of breath or dizziness during the test. Only one tester had a slight dizziness after the test for 1 hour and the test was terminated. The tester was mainly caused by personal differences and unaccustomedness of wearing masks. The testers’ general reaction is that the mask has poor air permeability and strong breathing discomfort, because when the mask’s air permeability is poor, the air exhaled by a person cannot be exchanged with the outside world, resulting in the accumulation of exhaust gas in the mask, and people will have difficulty breathing. , Make people feel uncomfortable; when the breathability of the mask is good, the air exhaled by the person can be well exchanged with the outside world, and the person will feel unblocked breathing. According to the interview results, the head-wearing type and the ear-wearing type of the same model of mask have a better fit to the face and a slightly stronger sense of breathlessness. Although the mask fits better with the face, it has the effect of blocking particles. The better, but the more airtight the mask, the more obvious the increase in respiratory resistance to the human body and the harder it is to breathe. Compared with masks of the same model, with breathing valve and without breathing valve, there is no big difference in the sense of breathing from the perspective of personnel experience.

are important in ensuring tensile tester manufacturers, and the machine is utilised by everyone from tensile tester manufacturers to tensile tester manufacturers.

If you are looking for a reputable textile testing equipment tensile tester manufacturers, you are on the lucky side as we are among the leading supplier in China. Visit the given links GESTER Instruments to know more.

With a complete manufacturing plant, GESTER International Co.,Limited is able to meet the most stringent specifications, no matter the type of product. A dedicated team of experts handle these value-added services, ensuring that customer needs are met on time, consistently monitoring quality and performance of textile testing equipment to the highest international standards. Visit GESTER Instruments to learn more.

GET IN TOUCH WITH Us
recommended articles
Everything You Need to Know About the Hydrostatic Head Tester
A hydrostatic head tester evaluates the waterproof capability of textiles, automotive interiors, and industrial materials. This guide covers its working principle, core components, global test standards (ISO, AATCC, EN), and a detailed testing procedure to ensure accurate results.
ISO 20344 Tester – Tested by ISO 20344 Standard
EN ISO 20344 is the core international test method standard for full-performance detection of safety footwear. This article systematically explains the full range of whole-shoe test items covered by the ISO 20344 standard, analyzes the core practical advantages of mandatory ISO 20344 testing for factories and laboratories, and matches a complete set of dedicated ISO 20344 testers one by one. It also sorts out mainstream associated safety footwear standards worldwide, providing one-stop standardized testing solutions for safety footwear manufacturers, third-party testing institutions and occupational safety supervision departments.
Technical Insight: How a Professional EN388 Gloves Tester Company Evaluates Durability
In industrial settings, protective gloves’ durability is critical for workplace safety, with the EN388 standard serving as the global benchmark for evaluating abrasion, cut, tear, and puncture resistance. GESTER International Co., Ltd., a professional EN388 gloves tester company with over 20 years of experience, delivers high-precision testing solutions to ensure accurate and reliable durability assessments. Equipped with advanced instruments like the Safety Glove & Shoe Upper Cutting Tester GT-KC29—featuring LCD display, real-time monitoring, and compliance with EN, ISO, and ASTM standards—GESTER’s solutions meet the rigorous demands of laboratories, manufacturers, and international testing institutes such as SGS, TUV, and Intertek. Adhering to ISO 9001 quality management systems and offering comprehensive after-sales support (installation, training, calibration), GESTER empowers clients to validate PPE performance, mitigate workplace risks, and achieve global regulatory compliance. For trusted EN388 gloves durability testing equipment and integrated laboratory solutions, GESTER is the preferred partner in the PPE industry.
Installation Training for the Incline Impact Tester GT-N49
Our expert team provides comprehensive on-site installation and training for the Incline Impact Tester GT-N49. This critical packaging testing equipment simulates real-world impacts during handling, transport, and stacking to evaluate product damage resistance. Learn about its key features like flexible moving plates, height adjustment, pneumatic angle control, and remote operation safety. Our service ensures proper setup, operational mastery, maintenance guidance, and troubleshooting support fo
Heat Contact Machine GT-C101-The Ultimate Selection Guide

The Heat Contact Machine GT-C101 is a specialized testing instrument designed for evaluating the heat resistance and thermal protective performance of gloves, protective clothing, and other heat-resistant materials used in high-temperature environments. In industries such as smelting, casting, welding, and glass manufacturing, workers are frequently exposed to intense heat, making accurate testing of contact heat resistance essential for ensuring safety and compliance.

GT-C101 simulates real working conditions by measuring heat transfer delay and thermal transmission under instant contact with high-temperature surfaces. Fully compliant with EN 407, EN 702, and ISO 12127-1 standards, this machine provides precise, repeatable data for manufacturers, laboratories, and research institutions. With high-temperature capability up to 500°C, advanced calorimetry, digital monitoring, and adjustable contact speed, the Heat Contact Machine GT-C101 is an indispensable tool for developing and certifying next-generation PPE and heat-insulation materials.
What Are the ISTA Standard Tests and ISTA Testing Equipment?
ISTA (International Safe Transit Association) standard tests are globally recognized transportation packaging test procedures designed to evaluate the safety and reliability of products and their packaging throughout the logistics chain. By simulating real-world transportation conditions such as drops, vibration, impact, stacking, and compression, ISTA testing helps identify potential packaging weaknesses before products enter large-scale distribution. ISTA testing equipment—including drop testers, vibration testers, incline impact machines, and compression testers—plays a critical role in accurately reproducing these conditions under laboratory settings. Proper selection and use of ISTA-compliant equipment enable manufacturers to reduce transportation damage, lower return costs, enhance packaging design, and improve customer confidence in product quality and logistics safety.
What is the Use of Air Permeability Tester?
An air permeability tester measures how easily air passes through textiles, nonwovens, and other materials, directly impacting comfort (heat/moisture management) and performance (wind resistance, filtration). This guide explains how digital testers work using pressurized airflow, details step-by-step testing procedures (including nozzle selection), and covers key applications in apparel, medical, automotive, and industrial sectors. Explore compliant standards (ISO 9237, ASTM D737, GB/T 5453) and
Everything You Need to Know About Programmable Temperature Humidity Chamber
A Programmable Temperature Humidity Chamber simulates environmental conditions to test product durability, stability (like shelf life & ageing), and performance across materials, electronics, automotive parts, food, and pharmaceuticals. This guide explains its five core systems (Control, Refrigeration, Heating, Humidity, Air Circulation) and their functions for precise testing.
What Are the Test Methods for Fabric Bursting Strength?
Fabric bursting strength measures resistance to rupture under concentrated load. Three primary test methods are used:

Ball Burst Method (ASTM D3787): Steel ball penetration for textiles/films using testers like GT-C02-2.

Hydraulic Method (ISO 13938.1): Fluid pressure on rubber diaphragm for industrial fabrics via GT-C12A.

Pneumatic Method (ISO 13938.2): Compressed air for breathable materials tested with GT-C12B.
Results are influenced by raw materials, yarn properties,
Why Is Shoe Slip Resistance Tester Important for Footwear Safety?
Slip resistance is one of the most critical performance indicators for modern footwear, especially safety shoes used in industrial and high-risk working environments. Slip and fall accidents frequently occur on wet or smooth surfaces, posing serious risks to workers and consumers. To prevent such accidents and improve product safety, footwear manufacturers widely use professional testing equipment such as Shoe Slip Resistance Tester and Footwear Slip Testing Machine. These devices simulate real walking conditions to measure the coefficient of friction between the shoe sole and various surfaces. This article explores the working principle, features, applications, and industry significance of shoe slip safety tester, explaining why accurate slip resistance testing is essential for footwear safety, product development, quality control, and compliance with international standards.
no data
Quanzhou Gester International Co.,Ltd gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059985379
Address:  Block 402,4th floor, f buliding, shengfulan business Center, no.577 jitai road, economic and  Technological development zone quanzhou of fujian.China.
Customer service
detect