loading

PPE Testing Equipment Manufacturer | Safety Equipment Testing Machines | GESTER


Products

Seven non-ferrous metal smelting pollutant discharge permit technical specifications released

On December 27, 2017, the Ministry of Environmental Protection issued the 'Technical Specifications for Pollution Discharge Permit Application and Issuance of Non-ferrous Metal Industry-Mercury Smelting' in the form of National Environmental Protection Standards (HJ) and 'Technical Specifications for Pollution Permit Application and Issuance of Non-ferrous Metal Industry-Magnesium Smelting' 'Technical Specifications for Pollution Discharge Permit Application and Issuance of Non-Ferrous Metal Industry-Nickel SmeltingSeven technical specifications including the application and issuance of pollutant permit application and technical specifications for non-ferrous metal industry-cobalt smelting and the 'Technical specifications for application and issuance of pollutant permit application and issuance of non-ferrous metal industry-antimony smelting' will take effect upon release, and enterprises in related industries can start in accordance with the requirements of the regulations. Declare the pollution discharge permit. Seven non-ferrous metal smelting pollutant discharge permit technical specifications are released. 1. Classification of discharge outlets Because the non-ferrous metal smelting industry has many production processes and many pollution sources, the management of the discharge outlets of the non-ferrous metal smelting industry should focus on the key points at this stage, combined with the 'Control of Pollutant Discharge' In order to improve the efficiency of pollution source control for non-ferrous smelting enterprises, improve the efficiency of pollutant discharge permit declaration and issuance, reduce the workload of accounting, and divide the discharge ports into main discharge ports and general discharge ports. Two categories are classified and managed. The principle of determining the main discharge outlets is that the discharge of pollutants is large, the types of pollutants are discharged, the installation of online monitoring facilities is convenient for assessment, and the 5+X types of pollutants (5 types are sulfur dioxide, nitrogen oxides, particulate matter, chemical oxygen demand, and ammonia nitrogen; Type X is total lead, total arsenic, total mercury, total cadmium, and fluoride. Pollutant discharge outlets that account for the largest part of the company's total discharge volume are set as the main discharge outlets to control the permitted discharge concentration and permitted discharge volume; other pollutants The discharge port is set as a general discharge port, which only controls the permitted discharge concentration.  The main waste water discharge outlets are the total discharge outlets of industrial waste water and the discharge outlets of workshops or production facilities. 2 Permitted emissions and actual emissions This standard focuses on combing the pollution emission factors of the five non-ferrous metal industry emission standards, combined with the 'Twelfth Five-Year Plan for the Comprehensive Prevention and Control of Heavy Metal Pollution' and the 'Atmospheric Ten ArticlesAccording to the requirements of relevant management documents such as 'Water Ten Articles   Pollution factors for the permitted emissions of exhaust gas are particulate matter, sulfur dioxide, nitrogen oxides (only applicable to pollutants in areas subject to special emission limits), lead and its compounds, arsenic and its compounds, mercury and its compounds, and cadmium and its compounds. The pollution factors for the permitted discharge of wastewater are chemical oxygen demand, ammonia nitrogen, total lead, total arsenic, total mercury, and total cadmium. Where there are local requirements for environmental quality improvement, the scope of pollution factor control for the permitted emission of non-ferrous industries can be expanded according to demand. For the discharge outlets of workshops or production facilities, the four heavy metals of total lead, total arsenic, total mercury, and total cadmium must be permitted in both the total amount and the permitted concentration. The other types of heavy metals are only permitted in concentration.   Permissible emissions include annual permissible emissions per pollutant discharge unit, annual permissible emissions from major outlets, and permissible emissions during special periods. Among them, the effective period of the annual permit emissions should be calculated from the time the permit is issued, rolling 12 months. The accounting method is as follows: the seven non-ferrous metal smelting emission permit technical specifications are released. The actual emission accounting method mainly distinguishes normal and abnormal conditions, as shown in the following figure: seven non-ferrous metal smelting emission permit technical specifications are released 3 new unorganized emission management requirements The issued 'Emission Standards for Pollutants from Tin, Antimony, and Mercury Industries' (GB30770) has become the most stringent standard for the heavy non-ferrous industry. Many standards are close to or stricter than foreign countries. According to the current feasible technical measures for pollution control, emission standards can be ensured. From the perspective of development trends, unorganized management and control should become the focus of emission reduction in the next stage of the industry. This technical specification focuses on the requirements of regulatory measures for unorganized emissions in the non-ferrous industry, through measures such as improvement of equipment airtightness and environmental smoke collection, this technical specification proposes to focus on on-site inspection of measures, supplemented by on-site monitoring to determine the enterprise's unorganized compliance status , Combining standards, regulations and the actual situation of the enterprise, the control of unorganized emission sources has been refined, and no specific requirements for the concentration and amount of specific permitted emissions are given.   Unorganized emission control requirements shall be implemented in accordance with the pollutant emission standard amendment form of the 'Non-ferrous Metal Industry Air Pollutant Emission Standard'. Seven non-ferrous metal smelting pollution discharge permit technical specifications are released 4 Self-monitoring management requirements The monitoring content mainly focuses on the discharge of exhaust gas (organized + unorganized) and wastewater (production, domestic wastewater, initial rainwater), and the environmental impact assessment will be approved after January 1, 2015 Enterprises, surrounding environmental impact monitoring points, and monitoring indicators shall be implemented in accordance with the requirements of the environmental impact assessment documents of the pollutant discharge unit.   The main discharge outlets allowable pollution factors: particulate matter, SO2, NOx, COD, NH3-N, pH, flow should be automatically monitored, and other factors can be automatically or manually monitored.   Unorganized emissions are monitored on a quarterly basis in accordance with the emission standards for the concentration of pollution factors at the boundary of the plant. 

GET IN TOUCH WITH Us
recommended articles
Leather Physical Properties Testing Guide
This guide details the 9 critical physical property tests essential for assessing leather quality: Tensile Strength, Tear Strength, Abrasion Resistance, Thickness, Water Vapor Permeability, Water Resistance, Shrinkage Temperature, Color Fastness to Friction, and Bending Strength. It covers the testing scope (natural leather, synthetic leather, finished products, semi-finished goods) and introduces specialized testing equipment required for each method (e.g., Universal Testing Machine, Elmendorf
 Fabric Pilling Test: How to Choose the Right ICI Pilling Box Tester GT-C18
Fabric pilling directly affects the appearance, durability, and perceived quality of textile products. With global textile brands enforcing stricter testing standards, reliable laboratory testing equipment has become essential for manufacturers. This article explores how fabric pilling tests are conducted and why textile laboratories increasingly invest in professional ICI pilling box testers such as the GT-C18. It explains the advantages of in-house testing, international compliance requirements, key machine components, and important parameters buyers should evaluate before purchasing a pilling tester. By selecting the right equipment, textile companies can achieve faster quality verification, reduce dependence on third-party laboratories, and ensure their fabrics consistently meet international market standards.
According to ASTM D642 Standard: Detailed Box Compression Strength Tester GT-N02A
The ASTM D642 standard defines the test method for determining the compressive resistance of shipping containers, like corrugated boxes, when faced with static compressive forces. This article details the test procedure and introduces the GESTER GT-N02A and GT-N02B Box Compression Testers, which are fully compliant with ASTM D642, ISO 12048, and TAPPI T804. These versatile machines perform destructive strength tests, constant value tests, and simulated long-term stacking tests to ensure your pac
Installation Training for the Incline Impact Tester GT-N49
Our expert team provides comprehensive on-site installation and training for the Incline Impact Tester GT-N49. This critical packaging testing equipment simulates real-world impacts during handling, transport, and stacking to evaluate product damage resistance. Learn about its key features like flexible moving plates, height adjustment, pneumatic angle control, and remote operation safety. Our service ensures proper setup, operational mastery, maintenance guidance, and troubleshooting support fo
Must-See Innovation: Leading Safety Helmets Tester Company at A+A International Trade Fair
The A+A International Trade Fair in Düsseldorf serves as the global hub for occupational safety and PPE innovation, where GESTER—an industry leader with over 20 years of R&D experience—shines as a top safety helmets tester company. This article explores the evolving global safety standards (ISO, ASTM, EN, ANSI) driving demand for advanced testing equipment, and highlights GESTER’s high-precision solutions for impact absorption, penetration resistance, and flame resistance testing. With ISO 9001 certification, computerized automation, real-time data capture, and a comprehensive global support framework (on-site installation, calibration, OEM/ODM services), GESTER empowers PPE manufacturers and laboratories to meet rigorous compliance requirements. The company’s presence at A+A underscores its commitment to bridging innovative PPE design with reliable safety validation, helping businesses accelerate time-to-market while ensuring worker protection worldwide.
What is the Safety Glove & Shoe Upper Cutting Tester GT-KC29
The Safety Glove & Shoe Upper Cutting Tester GT-KC29 is a high-precision testing instrument developed to measure the cut resistance performance of safety gloves and footwear uppers. In industrial and construction environments where sharp tools and metal edges pose significant injury risks, the GT-KC29 provides a reliable evaluation method by simulating real cutting motion. This tester meets EN 388 section 6.2, ISO 20344:2021 section 5.23, GB/T 20991 section 6.14, and other global standards, making it essential for PPE manufacturers, testing laboratories, and quality control departments. With automated operation, high repeatability, and multi-standard compliance, it helps companies improve product safety levels, enhance global competitiveness, and ensure superior protection for end users.
What is the Use of Air Permeability Tester?
An air permeability tester measures how easily air passes through textiles, nonwovens, and other materials, directly impacting comfort (heat/moisture management) and performance (wind resistance, filtration). This guide explains how digital testers work using pressurized airflow, details step-by-step testing procedures (including nozzle selection), and covers key applications in apparel, medical, automotive, and industrial sectors. Explore compliant standards (ISO 9237, ASTM D737, GB/T 5453) and
Why is TPP Testing Important for Firefighter Protective Clothing
TPP testing objectively evaluates the thermal protective performance of firefighter protective clothing under extreme radiant and convective heat. This article explains TPP testing principles, its role in meeting NFPA/ISO standards, and how advanced equipment like the GT-RC02 TPP tester helps ensure clothing reliability and firefighter safety.
What is Air Permeability Tester? Detailed Overview and Benefits

The air permeability tester is a high-precision testing instrument designed to evaluate the breathability of PPE materials, textile fabrics, non-woven fabrics, woven fabrics, and industrial filter media. It plays a critical role in quality control, product development, and laboratory research across multiple industries including PPE, textiles, automotive interiors, and filtration systems.

Modern instruments such as the GT-C27 Air Permeability Tester are developed with advanced sensor systems, automated control logic, and multi-standard compatibility to ensure reliable and repeatable results. Complying with global standards such as ISO 9237, ASTM D737, DIN 53887, and GB/T 5453, it guarantees internationally recognized testing performance.

With high automation, accurate pressure sensing, and flexible unit conversion systems, air permeability testing equipment significantly improves testing efficiency while reducing human error. It is widely used in PPE manufacturing, textile engineering, non-woven product development, and industrial filtration quality inspection.
Everything You Need to Know About Programmable Temperature Humidity Chamber
A Programmable Temperature Humidity Chamber simulates environmental conditions to test product durability, stability (like shelf life & ageing), and performance across materials, electronics, automotive parts, food, and pharmaceuticals. This guide explains its five core systems (Control, Refrigeration, Heating, Humidity, Air Circulation) and their functions for precise testing.
GESTER International Co., Ltd. gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059985379
Address:  Block 402,4th floor, f buliding, shengfulan business Center, no.577 jitai road, economic and  Technological development zone quanzhou of fujian.China.
Customer service
detect