loading

Gester Instruments | Professional Glove, Mask, Safety Helmet, Protective Clothing & Footwear Testing Equipment Manufacturer Since 1997


Products
Test Standard

Standard requirements for light sources in color light boxes1

The standard light source color light box is currently used in many industries. The main function of the standard light source color light box is the color matching and calibration of the appearance of the product. Many products have higher requirements on appearance and color, and some even directly affect the color. Due to the market sales of the product, the manufacturer must strictly control the appearance and color of the product, and the effect of the standard light source on the color light box is naturally highlighted. Therefore, the international statistical standards have made a series of requirements for the light source of the standard light source in the color light box. This article will focus on the requirements for marking the light source in the color matching phase. 1. Spectral requirements of the light source According to the requirements of ISO3664:2000, ordinary fluorescent tubes cannot be used as light sources for color observation, and special fluorescent tubes that meet the following technical requirements must be used: (1) The color temperature of the light source must be 5000K or 6500K, that is, observing the color under this light source color temperature is basically similar to the effect of observing the color under natural light from 8:00 am to 10:00 am and 3:00 pm to 5:00 pm in most parts of China. (2) The color rendering index Ra of the light source>90, that is, under this light source, more than 90% of the colors can be correctly observed. Second, the brightness of the light source requires a certain amount of illumination to observe the color of the object. It can be imagined that nothing can be seen in a dark room. According to the requirements of ISO3664:2000: (1) The brightness of the light source shining on the surface of the observed object through reflection should reach 2000Lux (+/-500Lux). The brightness of the illuminated surface is within the range of 1mX1m, and the brightness of any point shall not be lower than 75% of the brightness of the center of the illuminated surface. m2) (3) The brightness of the display should reach>75cd/m2 3. Requirements for the softness of the light source It is impossible to collect the light source and evenly and softly illuminate the surface of the illuminated object only by relying on a few standard light source tubes. This means that the standard observation light source must have a scientifically designed ambient light system to ensure that the energy of the light emitted by the fluorescent tube is irradiated as uniformly as possible on the surface of the illuminated object, and there is no light glare or light. shadow. 4. Requirements for the environment around the light source Observing color requires not only a standard light source and suitable light source brightness, but also strict requirements for the environment around the light source: (1) Other lighting sources around the observation light source cannot directly or indirectly affect the light source. Look at the surface of the object. (2) Observe the wall panels around the light source, the top and bottom (including the observer's own clothes) cannot use other colors, only the reflectivity can be used<60% neutral grey. (3) When observing color transmission photos, there must be a frame with a width of more than 50mm around the photo, and the color of the frame must be black.>90% black. 5. Color rendering index (Ra) The color rendering index is used to measure the ratio between the color that can be seen under the illumination of natural light and the color that can be seen under the illumination of a certain light source, that is, Ra=in a certain light source Colors that can be seen under illumination÷Colors that can be seen under natural light. Ra represents the color rendering index of a light source. The closer Ra is to 100%, the smaller the difference between the color displayed under the illumination of the light source and the color displayed under natural light. Note: Color temperature and color rendering index are two different physical concepts. Color temperature only reflects the color of the artificial light source, warmer or cooler. The color rendering index reflects the kinds of colors that can be displayed under the illumination of a light source. High color temperature does not mean high color rendering index, and high color rendering index does not mean high color temperature. 6. Color temperature (K) The color temperature of the light source is defined by the burning temperature when the color displayed by the light source is consistent with the color displayed when an absolute black body is burned at high temperature, and its unit is the absolute temperature Kelvin (K) . The higher the K value, the more white-blue the displayed color; the lower the K value, the more yellow-red the displayed color. 5000K (D50) is a standard light source tube with a slightly warmer (yellow) color tone, which is widely used in advertising art and prepress fields. But according to ISO3664:2000, this light source is now also mandatory in printing and other color management processes. 6500K (D65) is a standard light source tube with a slightly cooler (bluish) color tone. In the past in European and American countries, this light source was used in the printing field. But according to ISO3664:2000, this light source is gradually being replaced by the D50 light source. But in China, D65 light source is still the standard light source tube commonly used in the printing field. More about standard color matching light box: http://www.dsdengxiang.com/

GET IN TOUCH WITH Us
recommended articles
ISO 17694 / ISO 5402-1: Footwear Flexing Resistance Test Methods
Footwear soles and uppers endure thousands of flex cycles during use, risking premature cracking, delamination, or chipping if material resistance is inadequate. This technical analysis details two critical international standards:

1. ISO 5402-1: Specifies the flexometer method for testing leather flex resistance under repeated bending.

2. ISO 17694: Defines test methods for footwear upper and lining flex resistance, simulating real-world bending stress to assess long-term durability.

C
What is a Light Fastness Tester?
A Light Fastness Tester accelerates material aging by simulating sunlight (xenon lamps) and moisture to predict long-term durability. Used in textiles, automotive, plastics, and more, it follows AATCC TM 16, ISO 105-B02, and ASTM standards. Features include real-time light control, temperature/humidity regulation, and energy-efficient testing.
What are The Flame Retardant Test Methods ?
Flame retardant testing evaluates materials' ability to resist ignition and slow fire spread. This guide covers key textile test methods (45°, horizontal, vertical), standards (ASTM, ISO, BS), and equipment like flammability testers for upholstery, carpets, and fabrics.
Top Features of a Certified TDM Cut Resistance Tester Supplier for Laboratory Use
The demand for precise PPE safety testing has surged with the evolution of protective gear, making TDM (Tomodynamometer) cut resistance testing a critical process for evaluating protective gloves and industrial textiles. This article details the top features of a certified TDM cut resistance tester supplier for laboratory use, including compliance with international standards (EN 388, ISO 13997, ASTM F2992), high-precision mechanical engineering, automated workflows, robust data management, and integrated safety features. It highlights GESTER International Co., Ltd.—a 20+ year experienced manufacturer with ISO 9001 certification and partnerships with SGS, Intertek, and TUV—as a leading supplier, offering the GT-KC28 TDM Cut Test Machine and comprehensive services (on-site installation, calibration, global technical support). For laboratories seeking reliable, standard-compliant testing solutions to validate PPE safety claims, this article provides actionable insights into strategic procurement. Visit https://www.gesterinstruments.com/ for more technical specifications and PPE testing solutions.
Universal Testing Machine Dual Column GT-K01: A Reliable Solution for footwear Testing
The Universal Testing Machine Dual Column GT-K01 is a high-precision mechanical testing instrument widely used in the footwear industry to evaluate tensile, compression, bending, tearing, and bonding strength of various materials. With advanced servo control, high-accuracy displacement measurement, and compliance with multiple international testing standards such as SATRA, ASTM, ISO, and BS, the GT-K01 footwear universal testing machine provides reliable data for quality control, material research, and product certification. This article explores the working capabilities, structural features, and practical value of the GT-K01 universal testing machine in footwear testing and manufacturing processes.
How to Know the Fabric Shrinkage Test for Your Projects
Master fabric shrinkage testing with this definitive guide. Understand causes of shrinkage, industry standards (ISO, GB, AATCC), step-by-step testing methods using Wascator equipment, and strategies to minimize shrinkage for superior garment quality and customer satisfaction.
Mask Testing Equipment: Everything You Need to Know
This article comprehensively introduces mask testing equipment, including its definition, application significance, core international testing standards, main equipment types and functional characteristics. It also puts forward a step-by-step selection guide and common selection misunderstandings, providing a reference for mask manufacturers, third-party testing institutions and regulatory departments to select appropriate testing equipment, so as to ensure mask product quality, pass international certification and protect user safety.
Leather Physical Properties Testing Guide
This guide details the 9 critical physical property tests essential for assessing leather quality: Tensile Strength, Tear Strength, Abrasion Resistance, Thickness, Water Vapor Permeability, Water Resistance, Shrinkage Temperature, Color Fastness to Friction, and Bending Strength. It covers the testing scope (natural leather, synthetic leather, finished products, semi-finished goods) and introduces specialized testing equipment required for each method (e.g., Universal Testing Machine, Elmendorf
How to Improve the Accuracy of a Martindale Tester
Ensuring the accuracy of your Martindale abrasion and pilling tester is critical for reliable textile quality control. This guide details essential steps, from precise sample preparation and correct machine operation to routine maintenance. We also explore how advanced testers, like the GESTER model with its dual-servo drive and tool-free operation, are engineered to eliminate common sources of error and enhance testing precision for superior results.
What is the Safety Footwear Impact Tester & Why are They Important in Safety Shoes Testing
A Safety Footwear Impact Tester evaluates the impact resistance of safety shoes by striking the steel toe cap with 100J/200J kinetic energy, ensuring compliance with global standards (EN ISO 20344, ASTM F2412). It’s critical for verifying product protection, facilitating certification, and optimizing safety shoe design. GESTER Instruments offers reliable, user-friendly testers trusted by manufacturers and labs worldwide.
no data
Quanzhou Gester International Co.,Ltd gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059985379
Address:  Block 402,4th floor, f buliding, shengfulan business Center, no.577 jitai road, economic and  Technological development zone quanzhou of fujian.China.
Customer service
detect