loading

PPE Testing Equipment Manufacturer | Safety Equipment Testing Machines | GESTER


Products

Standard requirements for light sources in color light boxes1

The standard light source color light box is currently used in many industries. The main function of the standard light source color light box is the color matching and calibration of the appearance of the product. Many products have higher requirements on appearance and color, and some even directly affect the color. Due to the market sales of the product, the manufacturer must strictly control the appearance and color of the product, and the effect of the standard light source on the color light box is naturally highlighted. Therefore, the international statistical standards have made a series of requirements for the light source of the standard light source in the color light box. This article will focus on the requirements for marking the light source in the color matching phase. 1. Spectral requirements of the light source According to the requirements of ISO3664:2000, ordinary fluorescent tubes cannot be used as light sources for color observation, and special fluorescent tubes that meet the following technical requirements must be used: (1) The color temperature of the light source must be 5000K or 6500K, that is, observing the color under this light source color temperature is basically similar to the effect of observing the color under natural light from 8:00 am to 10:00 am and 3:00 pm to 5:00 pm in most parts of China. (2) The color rendering index Ra of the light source>90, that is, under this light source, more than 90% of the colors can be correctly observed. Second, the brightness of the light source requires a certain amount of illumination to observe the color of the object. It can be imagined that nothing can be seen in a dark room. According to the requirements of ISO3664:2000: (1) The brightness of the light source shining on the surface of the observed object through reflection should reach 2000Lux (+/-500Lux). The brightness of the illuminated surface is within the range of 1mX1m, and the brightness of any point shall not be lower than 75% of the brightness of the center of the illuminated surface. m2) (3) The brightness of the display should reach>75cd/m2 3. Requirements for the softness of the light source It is impossible to collect the light source and evenly and softly illuminate the surface of the illuminated object only by relying on a few standard light source tubes. This means that the standard observation light source must have a scientifically designed ambient light system to ensure that the energy of the light emitted by the fluorescent tube is irradiated as uniformly as possible on the surface of the illuminated object, and there is no light glare or light. shadow. 4. Requirements for the environment around the light source Observing color requires not only a standard light source and suitable light source brightness, but also strict requirements for the environment around the light source: (1) Other lighting sources around the observation light source cannot directly or indirectly affect the light source. Look at the surface of the object. (2) Observe the wall panels around the light source, the top and bottom (including the observer's own clothes) cannot use other colors, only the reflectivity can be used<60% neutral grey. (3) When observing color transmission photos, there must be a frame with a width of more than 50mm around the photo, and the color of the frame must be black.>90% black. 5. Color rendering index (Ra) The color rendering index is used to measure the ratio between the color that can be seen under the illumination of natural light and the color that can be seen under the illumination of a certain light source, that is, Ra=in a certain light source Colors that can be seen under illumination÷Colors that can be seen under natural light. Ra represents the color rendering index of a light source. The closer Ra is to 100%, the smaller the difference between the color displayed under the illumination of the light source and the color displayed under natural light. Note: Color temperature and color rendering index are two different physical concepts. Color temperature only reflects the color of the artificial light source, warmer or cooler. The color rendering index reflects the kinds of colors that can be displayed under the illumination of a light source. High color temperature does not mean high color rendering index, and high color rendering index does not mean high color temperature. 6. Color temperature (K) The color temperature of the light source is defined by the burning temperature when the color displayed by the light source is consistent with the color displayed when an absolute black body is burned at high temperature, and its unit is the absolute temperature Kelvin (K) . The higher the K value, the more white-blue the displayed color; the lower the K value, the more yellow-red the displayed color. 5000K (D50) is a standard light source tube with a slightly warmer (yellow) color tone, which is widely used in advertising art and prepress fields. But according to ISO3664:2000, this light source is now also mandatory in printing and other color management processes. 6500K (D65) is a standard light source tube with a slightly cooler (bluish) color tone. In the past in European and American countries, this light source was used in the printing field. But according to ISO3664:2000, this light source is gradually being replaced by the D50 light source. But in China, D65 light source is still the standard light source tube commonly used in the printing field. More about standard color matching light box: http://www.dsdengxiang.com/

GET IN TOUCH WITH Us
recommended articles
A Complete Guide to Martindale Testing by the Best Martindale Abrasion Tester Supplier
Durability is critical for textiles and footwear, and Martindale testing is the gold standard for measuring abrasion resistance and pilling performance. This guide dives into Martindale testing’s core mechanics (Lissajous figure multi-directional friction), strategies to boost testing accuracy (sample clamping, load calibration, abrasive standardization), and compliance with international standards (ISO 12947, ASTM D4966, EN). As a top Martindale abrasion tester supplier with 25+ years of expertise, GESTER International delivers high-precision instruments (Martindale Abrasion Tester GT-C13B, etc.) certified to ISO 9001 and trusted by SGS, Bureau Veritas, and other global testing institutes. Beyond machinery, GESTER offers global technical support, on-site installation, and calibration services. The guide also includes a procurement framework to help labs select tailored Martindale testing solutions. For reliable, standard-compliant durability testing, GESTER is your trusted partner.
ISO 20344 Tester – Tested by ISO 20344 Standard
EN ISO 20344 is the core international test method standard for full-performance detection of safety footwear. This article systematically explains the full range of whole-shoe test items covered by the ISO 20344 standard, analyzes the core practical advantages of mandatory ISO 20344 testing for factories and laboratories, and matches a complete set of dedicated ISO 20344 testers one by one. It also sorts out mainstream associated safety footwear standards worldwide, providing one-stop standardized testing solutions for safety footwear manufacturers, third-party testing institutions and occupational safety supervision departments.
Sweating Guarded Hotplate Buying Guide
Choosing the right Sweating Guarded Hotplate is essential for obtaining accurate thermal resistance (Rct) and water vapor resistance (Ret) data for textiles. This guide explains how Sweating Guarded Hotplate testing works, introduces international standards including ISO 11092 and ASTM F1868, compares the most important purchasing considerations, and answers common questions from textile laboratories and apparel manufacturers.
Analyzing the Sweating Guarded Hotplate GT-C98 & Why it is Important
The Sweating Guarded Hotplate GT-C98 is a professional textile testing instrument designed to measure thermal resistance and evaporative resistance of fabrics, garments, and personal protective equipment (PPE). By simulating heat and moisture transfer from human skin, the instrument provides reliable data for evaluating thermal comfort, breathability, and moisture management properties. This article explores the working principle, key features, applications, and importance of the GT-C98, helping manufacturers, laboratories, and researchers improve textile product development and quality assurance.
Why Is Shoe Slip Resistance Tester Important for Footwear Safety?
Slip resistance is one of the most critical performance indicators for modern footwear, especially safety shoes used in industrial and high-risk working environments. Slip and fall accidents frequently occur on wet or smooth surfaces, posing serious risks to workers and consumers. To prevent such accidents and improve product safety, footwear manufacturers widely use professional testing equipment such as Shoe Slip Resistance Tester and Footwear Slip Testing Machine. These devices simulate real walking conditions to measure the coefficient of friction between the shoe sole and various surfaces. This article explores the working principle, features, applications, and industry significance of shoe slip safety tester, explaining why accurate slip resistance testing is essential for footwear safety, product development, quality control, and compliance with international standards.
What is the Safety Footwear Impact Tester & Why are They Important in Safety Shoes Testing
A Safety Footwear Impact Tester evaluates the impact resistance of safety shoes by striking the steel toe cap with 100J/200J kinetic energy, ensuring compliance with global standards (EN ISO 20344, ASTM F2412). It’s critical for verifying product protection, facilitating certification, and optimizing safety shoe design. GESTER Instruments offers reliable, user-friendly testers trusted by manufacturers and labs worldwide.
Why is TPP Testing Important for Firefighter Protective Clothing
TPP testing objectively evaluates the thermal protective performance of firefighter protective clothing under extreme radiant and convective heat. This article explains TPP testing principles, its role in meeting NFPA/ISO standards, and how advanced equipment like the GT-RC02 TPP tester helps ensure clothing reliability and firefighter safety.
Why GESTER is Recognized as a Global Top Safety Shoe Tester Exporter
As global industrial safety requirements tighten, GESTER International Co., Ltd has emerged as a globally recognized top safety shoe tester exporter, serving 168 countries with over 25 years of specialized expertise. The company’s success hinges on its commitment to precision engineering, compliance with international standards (ISO, ASTM, EN, SATRA), and partnerships with renowned testing institutes like SGS, Intertek, and TUV. Its product lineup, including the Safety Glove & Shoe Upper Cutting Tester GT-KC29 and cut resistance testers, delivers reliable, repeatable data for safety footwear durability, cut resistance, and other critical performance indicators. Complemented by a comprehensive global service network (on-site installation, calibration, staff training) and OEM/ODM customization capabilities, GESTER streamlines quality control for manufacturers, facilitating market access and ensuring workplace safety. Trusted by PPE brands and laboratories worldwide, GESTER bridges technical excellence and practical usability to drive efficiency in safety shoe certification and global trade.
Technical Insight: How a Professional EN388 Gloves Tester Company Evaluates Durability
In industrial settings, protective gloves’ durability is critical for workplace safety, with the EN388 standard serving as the global benchmark for evaluating abrasion, cut, tear, and puncture resistance. GESTER International Co., Ltd., a professional EN388 gloves tester company with over 20 years of experience, delivers high-precision testing solutions to ensure accurate and reliable durability assessments. Equipped with advanced instruments like the Safety Glove & Shoe Upper Cutting Tester GT-KC29—featuring LCD display, real-time monitoring, and compliance with EN, ISO, and ASTM standards—GESTER’s solutions meet the rigorous demands of laboratories, manufacturers, and international testing institutes such as SGS, TUV, and Intertek. Adhering to ISO 9001 quality management systems and offering comprehensive after-sales support (installation, training, calibration), GESTER empowers clients to validate PPE performance, mitigate workplace risks, and achieve global regulatory compliance. For trusted EN388 gloves durability testing equipment and integrated laboratory solutions, GESTER is the preferred partner in the PPE industry.
What is the Safety Glove & Shoe Upper Cutting Tester GT-KC29
The Safety Glove & Shoe Upper Cutting Tester GT-KC29 is a high-precision testing instrument developed to measure the cut resistance performance of safety gloves and footwear uppers. In industrial and construction environments where sharp tools and metal edges pose significant injury risks, the GT-KC29 provides a reliable evaluation method by simulating real cutting motion. This tester meets EN 388 section 6.2, ISO 20344:2021 section 5.23, GB/T 20991 section 6.14, and other global standards, making it essential for PPE manufacturers, testing laboratories, and quality control departments. With automated operation, high repeatability, and multi-standard compliance, it helps companies improve product safety levels, enhance global competitiveness, and ensure superior protection for end users.
GESTER International Co., Ltd. gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059985379
Address:  No.15, Chifeng Road,Licheng Region, Quanzhou city of Fujian,PR China.
Customer service
detect