loading

PPE Testing Equipment Manufacturer | Safety Equipment Testing Machines | GESTER


Products

Test process of dust filtration test of automobile air conditioner filter

This section specifies a number of test methods for testing air conditioner filters for filtration of contaminants (including dust and pollen, etc.) entering the cabin air. This section is used to evaluate or compare the performance of cabin air filters and filter elements in the laboratory. Through the test, the following information of the filter can be given: pressure drop, classification filtration efficiency and ash storage capacity. Normative references The following documents contain provisions which, through reference in this standard, become provisions of this part. For dated references, all subsequent amendments (excluding errata content) or revisions do not apply to this section, however, parties to agreements based on this section are encouraged to study whether the latest versions of these documents can be used . For undated references, the latest edition applies to this section. ISO 12103-1:1997 Road vehicles—Dust for filter evaluation—Part 1: Arizona Test Dust DIN EN 779:2002 Air Filters for General Ventilation—Determination of filtration performance DIN EN 1822-1:1998 High-efficiency air filters (HEPA and ULPA)—Part 1: Grading, performance testing, marking. Test conditions 1. The temperature of the air inhaled in the air condition must be 23°C±2°C, 50% relative humidity±3%. The above temperature and humidity conditions must be maintained throughout the experiment for testing the ash storage G of the filter. A summary of the test conditions is shown in Table C.2. 2. The air in the air cleaning device must be filtered by a high-efficiency filter of at least H12 level defined by EN 1822-1, and the pre-stage of the high-efficiency filter must be configured according to EN 779 Defined medium filter at F7 or F8 level. Due to air purification requirements and protection of the test equipment, it is recommended that a similar device be installed on the exhaust side to capture dust penetrating the test specimen. 3. Test object ①, test dust The test dust uses A2 ash (fine ash) or A4 ash (coarse ash) as defined in ISO 12103-1. Before the test, the test dust should be at 105°C±5°It was used after drying for 4h under the condition of C. ②. Other test dusts For special requirements, other test dusts/aerosols can also be used, such as potassium chloride (KCl), mono- or polydisperse latex balls, plant pollen or other dusts. In this case, the test procedure and test conditions shall be agreed between the filter manufacturer and the user. Test equipment 1. Basic structure An example of the structural arrangement of the test equipment required to complete the test is shown in Figures A.1 to A.5. The specific dimensions of the main parts are given in Figure A.2. This device, at least from the dusting part to the sampling port on the air outlet side, should be of conductive material and grounded. The basic principle is to minimize the loss of dust particles. The test equipment that meets the specification must meet the requirements of Chapter 5 and Table C.1 and Table C.2. 2. Air supply Air supply should be prepared according to 4.1.2. It is required to install a flow adjustment device in the pipeline at the rear end of the airflow suction device, and the adjustment range is 150m3/h~680m3/h. The flow regulation is independent of the amount of test dust added to the filter and is required to be accurate to±2%. Requires seals from the airflow delivery ducts after the flow conditioning device. When the pressure difference inside and outside the pipeline reaches 500 Pa, the leaked flow rate should be less than 100 l/min. The size of the airflow guide components can be selected according to the actual situation. 3. Test channel The test channel is required to be arranged vertically. By suitable measures, such as adding guide plates, ensure that the airflow is evenly distributed across the transverse section. As shown in Figure A.2. 4. Test ash-adding device ①. The ash-adding device should be selected as an ash-adding device, so that the test dust selected according to Section 4.2 can be supplied evenly. During the test, it is required that the ash adding device will not change the original particle distribution of the test dust. ②. When the particle distribution density dilution device measures the classification and filtration efficiency, it may be mistakenly counted as large particles due to the possibility of small particles sticking together. A special dilution device is used to reduce the distribution density of dust particles. The device is installed on the dust supply pipe after the metering equipment, and can replace the dilution equipment before the particle counter. During the ash storage test, the dilution device should be closed. 5. The dust in the ash test should be introduced in the opposite direction of the airflow as shown in Figure A.2. It must be ensured that the test ash is evenly distributed in the test channel. The test channel must be of conductive material, and the intake air must be dry and free of oil. Once significant sampling errors have been ruled out through the tests of 5.6 to 5.9, the suitability of the test system can be verified, given that the test dust is uniform in the three-dimensional space. 6. Sampling tube The sampling tube is installed facing the air flow direction. Sampling tubes can be installed upstream and downstream of the test sample respectively; or only one sampling tube can be installed at the downstream position of the sample, respectively, to measure the two cases with and without the test sample installed. When sampling, the airflow velocity in the sampling tube is required to be as consistent as possible with the airflow around the sampling tube (isokinetic sampling). The deviation should be controlled at±within 20%. If a sampling tube is used in the upstream and downstream of the test sample, the two sampling tubes are required to be of the same specification and model, especially the requirements in Section 5.9.

GESTER International Co.,Limited is a gaint manufacturer of textile testing equipment, which is one of the most outstanding product produced from us.

To understand how efficiently works, go to GESTER Instruments for more information.

GESTER International Co.,Limited who primarily serve our consumers need to consider offering their products in an tensile tester manufacturers such as textile testing equipment to take advantage of the growing interest from consumers in supporting tensile tester manufacturers.

GESTER International Co.,Limited can assure you that we never compromise on our quality standards and are one of the best in the market at present.

We are professional in manufacturing textile testing equipment, and always emphasize the technology and quality during the producing procedure.

GET IN TOUCH WITH Us
recommended articles
What is EN 149 & Why is it Important?
EN 149 is the core European standard for particle-filtering half masks and FFP respirators. This article elaborates on the definition, structure, performance classification, marking rules and core advantages of EN 149, compares it with NIOSH N95, KN95, EN 143 and medical mask standards, and lists industry application scenarios, as well as professional mask and filter testing instruments compliant with EN 149 testing requirements.
Why TDM Cut Test Machine GT-KC28 Is Needed in PPE Testing

Cut resistance is one of the most critical performance indicators in personal protective equipment (PPE) testing, directly affecting worker safety in high-risk industries such as metal processing, machinery manufacturing, and emergency rescue. The TDM Cut Test Machine GT-KC28 plays a vital role in accurately evaluating the cut resistance of PPE products, including gloves, protective clothing, footwear materials, composite materials, rubber, and industrial textiles.

By adopting high-precision force control systems, intelligent data processing, and stable transmission technology, the GT-KC28 TDM Cut Tester can accurately measure the critical cutting force of materials and ensure excellent repeatability and comparability of test results. Its user-friendly touch-screen operation, comprehensive data storage, USB data export, and built-in thermal printer greatly improve laboratory efficiency and data traceability.

The TDM Cut Test Machine GT-KC28 fully complies with major international and national standards such as ISO 13997, EN 388, ASTM F2992/F2992M, ANSI/ISEA 105, and GB 24541-2022, making it a reliable solution for PPE manufacturers, third-party testing laboratories, and research institutions. Through precise and standardized cut resistance testing, the GT-KC28 helps reduce industrial cutting injuries, supports PPE certification across global markets, and ensures that protective equipment delivers reliable safety performance in real-world applications.
Leather Industry Innovations: GESTER at ACLE as a Footwear Testing Equipment Factory
The global leather and footwear industry is shifting toward prioritizing durability, material integrity, and functional excellence—driving demand for high-precision testing equipment. As a highlight of ACLE 2026 (All China Leather Exhibition), GESTER International Co., Ltd., a 25+ year footwear testing equipment factory, showcases innovative solutions tailored to this trend. Trusted by leading testing institutes like SGS, TUV, and Intertek, GESTER’s product lineup includes the Martindale Abrasion Tester (for surface durability), Tension Testing Machine (for mechanical properties), and Safety Shoe Cutting Tester—all compliant with ISO, ASTM, and EN standards. These instruments integrate automation (PLC systems) and data traceability to reduce human error, support ISO 9001 compliance, and streamline laboratory efficiency. With a global service network spanning 160+ countries, GESTER offers on-site installation, calibration, and software updates to ensure long-term usability. The article also outlines strategic procurement tips for manufacturers, emphasizing modular design, standard compatibility, and supplier track records. For leather and footwear brands seeking to enhance product reliability, avoid recalls, and stay competitive, GESTER’s ACLE 2026 innovations and end-to-end support provide a definitive quality assurance solution.
Cobb Test Paper Absorption Tester GT-N07 - A Comprehensive Guide
The Cobb Test Paper Absorption Tester GT-N07 is an essential instrument for evaluating the water absorption properties of paper and paperboard materials. This test, commonly known as the Cobb method, helps determine how much water paper can absorb over a specified time under controlled conditions—crucial for assessing its suitability in printing, packaging, and coating applications.
How to Choose the Right Glove Testing Equipment
Choosing the right glove testing equipment is essential for evaluating the safety, durability, and protective performance of gloves. This guide explains the main types of glove testing equipment, including thermal protection, cut and abrasion resistance, tensile strength, and environmental conditioning equipment. It also introduces key glove testing standards such as EN 388, EN ISO 13997, ISO 37, ASTM D412, ISO 12947, and related thermal protection standards. By understanding your testing requirements, applicable standards, sample conditioning needs, maintenance requirements, and budget, you can build a more efficient and standard-compliant glove testing laboratory.
Top Features of a Certified TDM Cut Resistance Tester Supplier for Laboratory Use
The demand for precise PPE safety testing has surged with the evolution of protective gear, making TDM (Tomodynamometer) cut resistance testing a critical process for evaluating protective gloves and industrial textiles. This article details the top features of a certified TDM cut resistance tester supplier for laboratory use, including compliance with international standards (EN 388, ISO 13997, ASTM F2992), high-precision mechanical engineering, automated workflows, robust data management, and integrated safety features. It highlights GESTER International Co., Ltd.—a 20+ year experienced manufacturer with ISO 9001 certification and partnerships with SGS, Intertek, and TUV—as a leading supplier, offering the GT-KC28 TDM Cut Test Machine and comprehensive services (on-site installation, calibration, global technical support). For laboratories seeking reliable, standard-compliant testing solutions to validate PPE safety claims, this article provides actionable insights into strategic procurement. Visit https://www.gesterinstruments.com/ for more technical specifications and PPE testing solutions.
PPE Testing Equipment: Complete Guide to Personal Protective Equipment Testing
PPE Testing Equipment is used to evaluate the safety, durability, and protective performance of personal protective equipment under controlled test conditions. This complete guide covers five major PPE testing categories: Safety Footwear Testing Equipment, Glove Testing Equipment, Protective Clothing Testing Equipment, Mask Testing Equipment, and Safety Helmet Testing Equipment. Learn about common PPE test methods, applicable standards, equipment types, laboratory requirements, and key factors to consider when selecting PPE Test Equipment for quality control, product development, certification, and laboratory applications.
Safety Footwear Tester Guide ISO 20346 with Buying Tips
This guide explains the ISO 20346 standard for general-purpose protective footwear, differentiates it from related ISO standards, and shares core buying tips for qualified safety footwear testers. It also introduces professional multi-standard compliant testing equipment for footwear quality control and compliance verification.
Mask Testing Equipment: Everything You Need to Know
This article comprehensively introduces mask testing equipment, including its definition, application significance, core international testing standards, main equipment types and functional characteristics. It also puts forward a step-by-step selection guide and common selection misunderstandings, providing a reference for mask manufacturers, third-party testing institutions and regulatory departments to select appropriate testing equipment, so as to ensure mask product quality, pass international certification and protect user safety.
PPE Testing Laboratory Equipment List
Setting up a PPE testing laboratory requires the right combination of instruments for safety footwear, gloves, protective clothing, masks and safety helmets. This guide explains the core testing equipment used in modern PPE laboratories, the standards they support, and the functions of each instrument, helping manufacturers, third-party laboratories and certification bodies choose a reliable and compliant testing setup.
GESTER International Co., Ltd. gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059985379
Address:  No.15, Chifeng Road,Licheng Region, Quanzhou city of Fujian,PR China.
Customer service
detect