Importance of Slip Resistance Testing in Footwear Quality Control


In footwear manufacturing, shoes serve diverse end‑use scenarios. Footwear experiences complex frictional interactions when users walk on wet, oily or contaminated floor surfaces. Workers in factories, medical staff, and daily consumers are exposed to slip‑and‑fall hazards every day. For safety footwear, work shoes, and general‑purpose footwear, slip‑resistance performance directly protects end‑users from fall‑related injuries.


To evaluate how well shoe soles resist slipping under real‑world walking conditions, a slip resistance tester is used. In this test, defined vertical load is applied to footwear sample against standard test floors, and horizontal friction force is captured during controlled sliding movement. This test is extremely critical because it reflects footwear safety performance for end‑users and verifies product compliance for global markets.


For example, industrial safety boots must maintain adequate friction on oily workshop floors to prevent workplace falls. Hospital non‑slip work shoes should deliver stable grip on water‑spilled ceramic floors.


Therefore, slip resistance tests are implemented to verify footwear safety and reliability. They also help brands and manufacturers meet global regulatory and buyer compliance requirements.

ISO 20344 vs SATRA TM144: Two Standards

ISO 20344 vs SATRA TM144 Slip Resistance Method

ISO 20344 Slip Resistance Method

The ISO 20344 standard is globally accepted for personal protective footwear test methods, including slip resistance assessment referenced to ISO 13287. It simulates real‑life walking contact conditions between footwear and test surfaces. Vertical normal force is applied onto footwear sample, followed by horizontal relative movement between shoe and test floor to measure dynamic friction coefficient.


This standard is widely adopted for European PPE certification and international safety footwear supply chains. If a pair of European‑spec safety boot is tested following ISO 20344 procedure, it may deliver a dynamic coefficient of friction reading of 0.32 under glycerin‑contaminated ceramic tile surface.

SATRA TM144

On the other hand, SATRA TM144 is a well‑known industry test method developed from human walking biomechanical research. It also measures dynamic friction coefficient, but enforces stricter timing requirements for load ramp‑up and data acquisition time‑point. This method closely replicates the exact moment of human gait when slipping is most likely to start.


It covers a broader range of test surfaces including ice, gravel, oil and water contaminants, not limited only to protective safety footwear. For instance, a non‑slip occupational shoe sample may show a 0.38 dynamic friction coefficient value under SATRA TM144 test setup. It supports comprehensive performance evaluation for buyers, labs and footwear developers.


Modern dual‑mode slip resistance testers such as GT‑KB48 are engineered to run both standards. This allows footwear factories to satisfy varied customer requirements without purchasing separate testing instruments.

To be fair, this is more of an optional maintenance schedule, and it generally combines different areas of both corrective and preventive maintenance.


Basically, condition‑based maintenance makes use of real‑time test‑data monitoring to diagnose possible maintenance needs for your universal testing machine before these needs grow into actual issues. It makes use of the actual machine condition, test repeatability and error feedback to determine possible requirements and offers recommendations for you to meet these needs before a failure happens.

Types of Footwear & Test Surfaces Covered by ISO 20344 and SATRA TM144

Types of Footwear & Test Surfaces Covered by ISO 2

Both standards target footwear slip‑resistance performance and evaluate friction under multi‑condition floor contact. But there are noticeable differences in applicable scenarios.

ISO 20344

ISO 20344 specifies slip‑resistance test procedures mainly for personal protective footwear. Typical samples include safety shoes, protective work boots certified against ISO 20345 series. Standard test surfaces are pressed ceramic tile and stainless steel plate with defined liquid contaminant like glycerin.

SATRA TM144

SATRA TM144 has wider application coverage. It works for nearly all footwear categories except pram shoes, outsole pieces, heel top‑pieces, and sheet soling raw materials. Test floors are not restricted to ceramic tile and stainless steel; ice, turf, gravel, oil, water and grease contaminants are all supported.


For example, outdoor anti‑slip boots tested on simulated icy surfaces can only be fully evaluated with SATRA TM144, as ISO 20344 does not cover ice test conditions. Footwear R&D labs often use SATRA TM144 for new outsole material comparison.

Comparison

Both standards calculate the dynamic friction coefficient of footwear. SATRA TM144 delivers more flexible test‑surface options for R&D and special‑condition evaluation, while ISO 20344 focuses strictly on regulatory compliance for protective footwear.

Testing Principles: ISO 20344 versus SATRA TM144

Slip‑Resistance Testing Principles: ISO 20344 versus SATRA TM144

ISO 20344 Slip‑Resistance Principle

ISO 20344 references the test method defined in ISO 13287. Footwear sample is secured on shoe last or prosthetic foot fixture. Pre‑load is applied and then ramped up to specified full normal force: 500±25 N for EU size 40 and above; 400±20 N for sizes below EU 40. After a defined static contact time, relative horizontal sliding movement runs at speed of (0.3 ±0.03) m/s.


Friction force is measured within a specified time window after sliding starts, and dynamic coefficient of friction is calculated as final result. This method was built for conformity assessment of safety protective footwear.


Potential limitation comes from fixture slippage. If footwear is not firmly clamped on shoe last during horizontal movement, unwanted sample shifting may bring deviation to measured friction values. Modern computer‑controlled slip‑resistance testers minimize human error via automated operation, precisely capturing force data curve for repeatable test results.

SATRA TM144 Slip‑Resistance Principle

SATRA TM144 also mounts footwear sample to shoe‑last or prosthetic foot fixture. However it applies stricter load‑ramp timing: normal force ramps from 50 N pre‑load to full test load within only 0.2 seconds. Sliding speed is kept at 0.3 m/s, with minimum sliding travel distance of 40 mm. The friction value is captured precisely at 0.10 ±0.01 seconds immediately after sliding movement initiates.


This test principle is derived from human‑gait biomechanical study, simulating the critical moment when slip occurs during natural walking. It supports versatile test media including ice, oil, water and gravel surfaces.


For example, winter safety outsole material can record a coefficient of friction of 0.28 on ice surface when running SATRA TM144 procedure.

Difference in Testing Principles

ISO 20344 and SATRA TM144 follow different timing rules for force ramping and friction‑data sampling. For this reason, test results for the identical shoe sample will not always match perfectly. SATRA TM144 captures friction at a very early instant of sliding movement, while ISO 20344 collects readings over a broader measurement time window.


Due to these differences, advanced multi‑standard slip‑resistance testers like GT‑KB48 support both ISO 20344 and SATRA TM144 test sequences on one single instrument. It enables factories and labs to meet both regulatory compliance and product‑development needs.

Specimen Preparation and Conditioning Requirements

Mounting, Number of Test Samples and Pre‑Conditioning

Specimen preparation and sample mounting are vital steps for slip‑resistance testing. Under both ISO 20344 and SATRA TM144 standards, footwear samples must be properly secured on shoe‑last or prosthetic‑foot fixture to prevent shifting during sliding. Outsole contact surface shall keep original production status without artificial damage or contamination.


Whole finished footwear is preferred for testing. In some pre‑development stages, outsole components or sheet soling materials can be used as test pieces and noted clearly in test report. There are visible differences on required sample repetitions.

ISO 20344

ISO 20344 requires repeated test cycles on each footwear specimen, and specified minimum sample quantity for PPE footwear batch evaluation. Final slip‑resistance result is calculated as average value of valid repeated measurements. Pre‑conditioning is required under standard laboratory atmosphere for protective footwear specimens before test execution.

SATRA TM144

SATRA TM144 specifies minimum 5 valid repeated sliding runs for each footwear sample to get reliable average friction coefficient. This repeated‑test requirement is critical especially for outsoles with complex tread patterns, where inter‑run variation is more likely to appear.

Pre‑Conditioning

Before starting slip‑resistance measurement, footwear samples shall be conditioned under standard laboratory atmospheric environment. Stable temperature and humidity ensure consistent outsole material hardness and surface property. Material hardness of rubber and polymer outsoles changes with temperature and humidity, and will directly affect friction coefficient output. For example, rubber outsole will become harder under low‑temperature environment and deliver different slip‑resistance readings.

Minor Differences in Preparation and Their Impact

Both standards share similar sample‑mounting logic, yet small procedural differences will lead to slight result deviation.


For SATRA TM144, operators must strictly control load‑ramp‑up time to finish transition from pre‑load to full normal force within 0.2 seconds; instrument servo and load‑cell performance is highly demanding. If timing requirement is not satisfied, measured friction coefficient will shift.


For ISO 20344, operators need to focus on footwear fixture tightness and static‑contact‑time setup. Slippage between shoe sample and shoe‑last fixture will cause unreliable test data.


Due to those procedural distinctions, the exact same pair of footwear may produce slightly different friction‑coefficient readings. For instance, a safety work boot can show CoF 0.32 under ISO 20344 and CoF 0.35 under SATRA TM144. Such gap comes not from footwear quality difference, but test‑method specification. That explains many export‑oriented footwear labs generate separate test reports according to ISO 20344 and SATRA TM144 for different customers.

Test Equipment and Operational Differences

Footwear Slip Resistance tester gt-KB48

Instruments Specified by ISO 20344 vs SATRA TM144

Slip‑resistance test standards define instrument requirements to guarantee repeatable and comparable test data. Proper hardware configuration is essential for valid test reports.

ISO 20344 Compliant Slip‑Resistance Tester

The tester for ISO 20344 must provide adjustable vertical normal‑force output, horizontal load‑cell for friction‑force acquisition, controlled sliding speed at 0.3 m/s, and standard test floors including pressed ceramic tile and stainless steel plate. Computer‑controlled system records force‑time curves automatically. This configuration is widely deployed by European notified‑body laboratories for PPE footwear certification.

SATRA TM144 Compliant Slip‑Resistance Tester

SATRA TM144‑capable tester needs high‑speed servo drive system, fast‑response vertical‑force cylinder to finish 50 N‑to‑full‑load ramp within 0.2 seconds, and high‑precision load‑cells for capturing friction signal at the exact 0.1 s time‑point after sliding onset. Apart from standard tile and stainless‑steel plates, users can install optional test surfaces such as ice tray to fulfil extended‑surface test requirements.

Operational Details: Load, Timing, Fixture and Calibration

Operational parameters between ISO 20344 and SATRA TM144 create major sources of result divergence.


Load Application & Timing


ISO 20344 defines static‑contact‑time and acceptable time window for building normal force. SATRA TM144 sets much tighter limit for load‑ramp‑up duration, and defines exact 0.1 s data‑capture point after sliding movement starts. Too slow load‑ramp will invalidate SATRA TM144 measurement.


Fixture and Test Surfaces


Both standards require shoe‑last or prosthetic‑foot fixture to hold footwear sample firmly. SATRA TM144 supports more optional test surfaces beyond ceramic tile and stainless steel. Loose mounting of footwear will cause abnormal low friction readings for both standards.


Calibration


Regular instrument calibration is mandatory for ISO 20344 and SATRA TM144. Calibration includes vertical‑load‑cell verification, horizontal‑friction‑load‑cell check, sliding‑speed confirmation, and surface‑reference calibration block test. ISO 20344 calibration focuses on PPE conformity‑assessment accuracy; SATRA TM144 calibration additionally validates high‑speed force‑response and timing precision.

Result Expression and Calculation Methods

Units of Slip‑Resistance Expression

Both ISO 20344 and SATRA TM144 calculate the dynamic coefficient of friction (CoF), a dimensionless value without physical unit. Higher coefficient of friction indicates better slip‑resistance performance of footwear sample on given contaminated test surface.


For example, a qualified safety boot may deliver dynamic CoF of 0.32 under glycerin‑lubricated ceramic tile test. High‑performance anti‑slip occupational footwear may reach CoF 0.40 under same surface condition.

ISO 20344

For ISO 20344, multiple repeated sliding tests are performed on footwear specimen, and final test result is reported as average dynamic coefficient of friction. Report must document test‑surface type, contaminant medium, applied normal force level, sliding speed and sample information. This report format fits European PPE certification submission. ISO 20344 report mainly outputs average friction coefficient for compliance judgment.

SATRA TM144

SATRA TM144 completes minimum 5 valid sliding repetitions. Final result is average dynamic coefficient of friction captured at 0.10 ± 0.01 seconds right after sliding starts. Test report needs to record full set of conditions: test floor material, contaminant type, normal force magnitude, load‑ramp‑up time, sliding distance and individual run readings. This detailed dataset provides footwear developers extra insights for outsole material and tread‑pattern optimization.

Pros and Cons: Applicability of ISO 20344 vs SATRA TM144

Strengths and Limitations of ISO 20344

ISO 20344 is the harmonised European standard document widely used for protective‑footwear PPE certification across EU territory. Its biggest advantage is official regulatory recognition for safety‑footwear market access. European notified bodies accept ISO 20344 slip‑resistance test reports for product conformity assessment. Many historical certification records are built on this standard.


But ISO 20344 has its limitations. Test‑surface choices are limited mainly to ceramic tile and stainless‑steel plate with glycerin contaminant. It does not define testing procedures for special surfaces such as ice, gravel or turf. So it is not ideal for R&D evaluation of winter‑use or special‑scenario anti‑slip footwear.

Strengths and Limitations of SATRA TM144

SATRA TM144 is built on human‑walking biomechanical research, simulating the critical moment when slip occurs during natural gait. It supports a broad portfolio of test surfaces including ice, oil, grease, water, turf and gravel. This makes it extremely valuable for footwear R&D and new‑outsole‑material comparison.


SATRA TM144 captures friction coefficient at a precise early time‑point of sliding, providing detailed repeated‑run raw data for technical analysis. This helps R&D teams compare tread pattern and compound formulation performance.


One downside of SATRA TM144 is its very strict instrument‑timing requirement. The tester must complete normal‑force ramp‑up within 0.2 seconds, which raises requirements for servo‑motor and pneumatic cylinder hardware. Older test equipment may fail to fulfil such timing specifications. Another limitation: SATRA TM144 is an industry test method, not the official harmonised EU regulatory standard, so SATRA‑only report cannot replace ISO 20344 documentation for PPE certification application in European market.

FAQs

What is slip‑resistance testing in footwear?

Slip‑resistance testing measures the dynamic friction coefficient between footwear outsole and test floors, to evaluate footwear’s ability to resist slip‑and‑fall hazard under walking‑simulated conditions.


What is the main difference between ISO 20344 and SATRA TM144?

ISO 20344 is EU harmonised PPE‑footwear test standard focused on regulatory certification. SATRA TM144 uses strict biomechanical timing rules, supports wider variety of test surfaces for footwear R&D.


Which footwear samples are commonly tested for slip‑resistance?

Safety protective footwear, occupational work shoes, winter anti‑slip boots, outsole components and sheet soling materials.


Why will test results differ between ISO 20344 and SATRA TM144?

Differences come from load‑ramp‑up timing rules, friction‑data‑capture time‑point and available test surfaces, not defects of footwear sample itself.


Which standard should global footwear exporters follow?

Use ISO 20344 for EU PPE certification. Use SATRA TM144 for product development and special‑surface performance assessment. Many export‑oriented labs run both standards on dual‑mode testers.

f

Contact Us for a Free Demo or Consultation

For more information on footwear slip‑resistance test methods and standards

Or footwear slip‑resistance testing machines, contact us:

. 

- Email: info@gester-instruments.com

Contact GESTER for footwear slip‑resistance testing machine
prev
How to Select an Abrasion Tester for Different Footwear Materials
Recommended for you
Get in touch with us
GESTER International Co., Ltd. gains certificates of ISO 9001, 3A and SGS Audited supplier etc. with advanced design concept, excellent manufacturing technology and strict quality control.
WeChat
Contact us
Tel: +86-595-28886108 
Fax: +86-595-22515221
E-mail: sales10@gester-instruments.com,
                 info@gester-instruments.com
Mobile/Whatapp/ Wechat:  
             + 86(0)18059983973
Address:  No.15, Chifeng Road,Licheng Region, Quanzhou city of Fujian,PR China.
Customer service