GESTER PPE Testing Equipment | Professional Safety Footwear Testing Equipment, Glove Testing Equipment, Protective Clothing Testing Equipment
High temperature safety helmet Pretreatment equipment
Product Description
Developed and manufactured in accordance with the latest national standard GB/T 2811 《Head Protection - Safety Helmets》 and EN standards. It is mainly used for preconditioning safety helmets at an extremely high temperature of 150°C±5°C for 1 hour, followed by impact and puncture tests. The entire test process is fully automatic: the headform automatically enters and exits the chamber without manual operation, preventing high-temperature hazards to operators.
Standards
EN,GB/T 2811
Features of safety helmet high temperature pretreatment tank
1. Test device: Fully automatic test process, easy and simple to operate.
2. Temperature control device: Precisely controls the test temperature required by standards.
Alarm device: Equipped with test pre-alarm function, helping operators prepare in advance for tests after preconditioning and ensuring tests are completed within 1 minute after taking out the safety helmet.
Product Specifications
| Model | GT-SH08 |
| Temperature control | The chamber is thermally insulated, with a maximum controllable internal temperature of 200°C |
| Temperature sensor | PT100, accuracy ±1°C |
| Opening size | 250mm × 300mm |
| Metal thickness | >1.5 mm; built-in circulating air cooling to maintain temperature at 50°C±2°C |
| Lifting mechanism | Directly connected to the temperature‑controlled headform, automatically lifting the headform into the chamber. |